Hearth and Home Technologies 6000GCF-IPIL E. Vent Diagrams, Top Vent - Horizontal Termination

Models: 6000GCF-IPIL 6000GCF-IPI

1 61
Download 61 pages 49.31 Kb
Page 24
Image 24
E. Vent Diagrams

E. Vent Diagrams

 

 

 

 

Top Vent - Horizontal Termination

 

WARNING

 

 

 

 

Note: The 6000 series fireplaces can adapt to

Fire Risk.

Explosion Risk.

 

 

Do NOT pack insulation or other combustibles

SLP series vent pipe, if desired.

between ceiling firestops.

 

 

When venting off the top of the unit, use a DVP-2SL adapter and

• ALWAYS maintain specified clearances around

a minimum 48 inch vertical section of SLP series vent pipe.

venting and firestop systems.

 

After the 48 inch vertical section, the venting table rules

• Install wall shield and ceiling firestops as speci-

must be followed. The first 48 inch vertical section is NOT

fied.

 

 

 

Failure to keep insulation or other material away

counted as part of the vertical components in the table. It is

still counted as part of the overall maximum run. All venting

from vent pipe may cause fire.

 

 

 

 

 

table rules for the vent run must still be followed.

 

 

 

 

 

 

WARNING

 

Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal
Fire Risk.

 

 

 

SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal
• When using DVP-HRC-SS and DVP-HRC-ZC-

 

SS termination caps on top vented fireplaces, a

 

6 inch minimum vertical vent section is required

Top Vent - Horizontal Termination

before installing first elbow.

 

 

 

 

 

One Elbow

V1 Minimum

H1

Maximum

6 inches

152 mm

3 ft.

914 mm

 

 

1 ft.

305 mm

3 ft.

914 mm

 

2 ft.

610 mm

6 ft.

1.8 m

 

3 ft.

914 mm

9 ft.

2.7 m

V1

4 ft.

1.2 m

12 ft.

3.7 m

H1

V1 + H1 = 40 ft. (12.2 m) Maximum

 

 

H1 = 20 ft. (6.1 m) Maximum

 

V1 = 6 inches (152 mm) Minimum

Figure 7.3

Two Elbows

H2

V1

H1

 

V1 Minimum

H1 + H2 Maximum

1 ft.

305 mm

Cannot do

1 1/2 ft.

457 mm

1-1/2 ft.

457 mm

2 ft.

610 mm

3 ft.

914 mm

 

 

 

 

3 ft.

914 mm

6 ft.

1.8 m

 

 

 

 

4 ft.

1.2 m

9 ft.

2.7 m

V1 + H1+ H2 = 50 ft. (15.2 m) Maximum

H1 + H2 = 17 ft. (5.2 m) Maximum

V1 = 1 ft. (305 mm) Minimum

 

INSTALLED

Figure 7.4

HORIZONTALLY

 

24

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. H • 11/08

Page 24
Image 24