Hearth and Home Technologies 6000GCF-IPIL Appliance Setup, A. Remove Fixed Glass Assembly

Models: 6000GCF-IPIL 6000GCF-IPI

1 61
Download 61 pages 49.31 Kb
Page 46
Image 46
14 Appliance Setup

14 Appliance Setup

A. Remove Fixed Glass Assembly

See Section 14.I.

B. Remove the Shipping Materials

Remove shipping materials from inside or underneath the firebox.

C. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.

D. Accessories

Install approved accessories per instructions included with accessories. Contact your dealer for a list of ap- proved accessories.

WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty.

E. Removing Optional GFK-160A Fan

ITEM

SEE FIGURE 14.1

1

Remove front from the fireplace.

2

Remove glass assembly from the fireplace.

3

Remove logs.

4

Remove grate.

5

Remove optional side and back refractory.

6

Remove burner assembly.

7

Remove valve assembly.

8

Disconnect fan and remove it through the valve
assembly cavity (see Figure 14.2).

 

Figure 14.1

4

6

A. Remove Fixed Glass Assembly7

B. Remove the Shipping Materials2

1C. Clean the Appliance

REMOVE FAN THROUGH

8

VALVE ASSEMBLY CAVITY

 

Figure 14.2

 

RHEOSTAT

Figure 14.3 Rheostat Location

46

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. H • 11/08

Page 46
Image 46