and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation
of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each appliance is meticulously fabricated and gold and nickel surfaces are
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: ON BACK OF APPLIANCE
|
|
|
|
|
|
|
|
|
|
|
| SERIAL NO. |
|
|
| |
|
|
|
|
| MODEL / MODÈLE: SAPPHIRE |
|
|
| ||||||||
|
|
| Portland |
|
|
|
|
|
| 007 |
|
|
|
|
| |
|
|
|
|
|
| VENTED GAS | FIREPLACE HEATER |
|
|
|
| 1445 North HIghway | ||||
|
|
|
|
| FOURNAISE AU GAZ AVEC VENTILATION |
|
|
| ||||||||
| Report No. / Rapport Numéro |
|
| NOT FOR USE WITH SOLID FUEL / |
|
|
| Colville, WA 99114 | ||||||||
|
| NE PAS UTILISER AVEC LE COMBUSTIBLE |
|
|
| www.quadrafire.com | ||||||||||
|
|
|
|
|
|
| SOLIDE |
|
|
|
|
|
|
|
| |
| APPROVED |
| FOR CANADA AND USA TO: |
|
|
|
| APPROUVÉ POUR LE CANADA ET LES | ||||||||
| ANSI Z21.88A |
| ANSI | |||||||||||||
| applicable sections of UL307b Gas Burning Heating Appliances for Manufactured | et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour | ||||||||||||||
| Homes and Recreational Vehicles, CAN/CGA | les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA | ||||||||||||||
| for use at High Altitudes.” This appliance is manufactured for operation with | Fired Appliances for use at High Altitudes”. Cet appareil est manufacturé | ||||||||||||||
| Natural Gas. |
|
|
|
|
|
|
| pour l’opération avec le Gaz Naturel. Pour une conversion au gaz propane | |||||||
| For conversion to propane Manufacturer’s Part | les pièces du Manufacturier | ||||||||||||||
| be used. This appliance may be installed in a bedroom or bedsitting room; in | utilisées. Cet appareil peut être utilisé dans une chambre à coucher ou salle | ||||||||||||||
| Canada remote thermostat installation is required. |
|
| de séjour; au Canada, l’installation d’un thermostat à distance est exigée. | ||||||||||||
| FAN TYPE VENTED CIRCULATOR / VENTILATEUR | Thermal Efficiency / Efficacité Thermique* |
| |||||||||||||
|
|
| CIRCULATOIRE |
|
|
|
|
|
| 84% NG (blower on / avec ventilateur allumé) |
| |||||
| Blower Electrical Rating / Évaluation du Ventilateur |
|
|
|
| 82% LP (blower on / avec ventilateur allumé) |
| |||||||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| Électrique: |
|
|
|
| * With Maximum horizontal length. / Avec longueur horizontale maximum. |
| ||||||
|
| 115 V., 1.5 Amps, 60 Hz, 150 Watts |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| For use with Natural Gas | For use with Propane |
|
|
|
|
| ||||
|
|
|
|
|
| Usage au Gaz Naturel | Usage au Gaz Propane |
|
|
|
| |||||
Top Vent: Input Rate on “HI” (BTU/Hr) |
| Bouche Supérieure: Puissance Évaluée à “HI” (BTU/Hr) | ||||||||||||||
| 30,000 | 30,000 | ||||||||||||||
| Input Rate on “LO” (BTU/Hr) |
| 21,000 | 24,500 |
| Puissance Évaluée à “LO” (BTU/Hr) | ||||||||||
| Maximum Output (BTU/Hr) |
| 25,000 | 24,600 |
| Puissance Maximum (BTU/Hr)** | ||||||||||
| Main Burner Orifice |
|
|
| .1065 (36DMS) | .0635 (52DMS) |
| Orifice du Brûleur Principal | ||||||||
Rear Vent: (No vertical) Input Rate on “HI” (BTU/Hr) | 26,000 | 26,000 | Conduit postérieur: Puissance Évaluée (non vertical) à “HI” (BTU/Hr) | |||||||||||||
| Input Rate on “LO” (BTU/Hr) |
| 18,000 | 20,000 |
| Puissance Évaluée à “LO” (BTU/Hr) | ||||||||||
| Main Burner Orifice |
|
|
| .0960 (41DMS) | .0595 (53DMS) |
| Orifice du Brûleur Principal | ||||||||
Minimum Inlet Pressure (Inches W.C.) |
| 4.5” | 11” | Pression Minimum de la Valve (pouces W.C.) | ||||||||||||
Maximum Inlet Pressure (Inches W.C.) |
| 7.0” | 14” | Pression Maximum de la Valve (pouces W.C.) | ||||||||||||
Manifold Pressure on “HI” (Inches W.C.) |
| 3.5” | 10” | Pression du Collecteur d’ Échappement à “HI” (pouces W.C.) | ||||||||||||
**Max. Venting, Blower On |
|
|
|
|
|
|
|
| ** Ventilation Maximum, Ventilateur Allumé | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
CAUTION: DO NOT OPERATE THIS APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. |
|
| OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED | |||||||||||||
SERVICE PERSON. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
ATTENTION: CET APPAREIL NE DOIT PAS ÊTRE OPÉRÉ SI LA VITRE EST BRISÉE, CRAQUÉE OU ENLEVÉE. LE REMPLACEMENT DU PANNEAU DOIT ÊTRE FAIT PAR UNE PERSONNE | ||||||||||||||||
LICENSÉE ET QUALIFIÉE. |
|
|
|
|
| REPLACEMENT |
|
|
|
| ||||||
|
|
|
| MINIMUM CLE R NCES TOCOMBUSTIBLES | / ESPACE MINIMUM AUX COMBUSTIBLES |
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS AY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
ATTENTION: CHAUD LORQU’IL EST EN OPÉRATION. NE TOUCHEZ PAS. DES BRÛLURES SÉVÈRES PEUVENT EN RÉSULTER. GARDEZ LES ENFANTS, LES VÊTEMENTS, LES MEUBLES, LA GAZOLINE | ||
| ALTERATION, | |
ET LES AUTRES LIQUIDES DE VAPEUR INFLAMMABLE ÊLOIGNÉS | ||
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, |
| SERVICE OR AINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION |
MANUAL PROVIDED WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFOR ATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. | ||
AVERTISSEMENT: UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICE OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES DOMMAGES MATÉRIELS. | ||
| VEC CET PP REIL. POUR ASSISTANCE OU DES INFORMATIONS SUPPLÉMENTAIRES CONSULTEZ UN INSTALLATEUR |
QUALIFIÉ, UNE AGENCE DE SERVICE OU UN FOURNISSEUR DE G Z.
Minimum clearances required from combustible construction for all appliance surfaces. / Espaces minimum exigés de la construction | ||||
combustible aux surfaces de l’appareil. |
|
|
| |
| F | C |
|
|
|
| G |
| |
|
| D | A | A |
|
|
|
| |
| B |
|
|
|
| E | C |
|
|
A | A |
|
| |
|
|
| ||
A. | Side of stove top to side wall | 6 in. (152 mm) |
| Du coté du poêle au coté du mur |
B. | Rear of stove top to back wall | 3 in. (76 mm) | Le contrôle arrière au mur arrière | |
C. | Corner of stove top to side wall | 1 in. (25 mm) | Du Coin du Poêle au coté du mur | |
D. | Minimum Alcove Height | 54 in. (1372 mm) | Hauteur minimum de l'alcôve | |
E. | Maximum Alcove Depth | 36 in. (914 mm) | Profondeur maximum de l'alcôve | |
F. | Minimum Alcove Width | 36 in. (914 mm) | Largeur minimum de l'alcôve | |
G. | Mantle Clearance from stove top | 23 in. (584 mm) | Espace libre du poéle au manteau |
HEARTH: A
CHEMINÉE: Un coussinet
Date of Manufacture / Date du Manufacturier
| 2008 2009 2010 Jan Feb Mar Apr May Jun | Jul | Aug Sep Oct | Nov Dec |
|
|
| DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE | Made in U.S.A. / Fait Aux | ||||
|
Serial Number
Barcode
Model Name
Test Lab & Report No.
Manufactured Date