and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation

of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each appliance is meticulously fabricated and gold and nickel surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: ON BACK OF APPLIANCE

 

 

 

 

 

 

 

 

 

 

 

 

SERIAL NO.

 

 

 

 

 

 

 

 

MODEL / MODÈLE: SAPPHIRE

 

 

 

 

 

 

Portland

 

 

 

 

 

 

007

 

 

 

 

 

 

 

 

 

 

 

VENTED GAS

FIREPLACE HEATER

 

 

 

 

1445 North HIghway

 

 

 

 

 

FOURNAISE AU GAZ AVEC VENTILATION

 

 

 

 

Report No. / Rapport Numéro

 

 

NOT FOR USE WITH SOLID FUEL /

 

 

 

Colville, WA 99114

 

061-S-19b-5

 

NE PAS UTILISER AVEC LE COMBUSTIBLE

 

 

 

www.quadrafire.com

 

 

 

 

 

 

 

SOLIDE

 

 

 

 

 

 

 

 

 

APPROVED

 

FOR CANADA AND USA TO:

 

 

 

 

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS:

 

ANSI Z21.88A

-2000 / CSA 2.33a-M00 Vented Gas Fireplace Heaters, and

ANSI Z21.88a-2000 / CSA 2.33a-M00 Fournaises au Gaz avec Ventilation,

 

applicable sections of UL307b Gas Burning Heating Appliances for Manufactured

et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour

 

Homes and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances

les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas

 

for use at High Altitudes.” This appliance is manufactured for operation with

Fired Appliances for use at High Altitudes”. Cet appareil est manufacturé

 

Natural Gas.

 

 

 

 

 

 

 

pour l’opération avec le Gaz Naturel. Pour une conversion au gaz propane

 

For conversion to propane Manufacturer’s Part #844-9730 and instructions must

les pièces du Manufacturier #844-9730 et ses instructions doivent être

 

be used. This appliance may be installed in a bedroom or bedsitting room; in

utilisées. Cet appareil peut être utilisé dans une chambre à coucher ou salle

 

Canada remote thermostat installation is required.

 

 

de séjour; au Canada, l’installation d’un thermostat à distance est exigée.

 

FAN TYPE VENTED CIRCULATOR / VENTILATEUR

Thermal Efficiency / Efficacité Thermique*

 

 

 

 

CIRCULATOIRE

 

 

 

 

 

 

84% NG (blower on / avec ventilateur allumé)

 

 

Blower Electrical Rating / Évaluation du Ventilateur

 

 

 

 

82% LP (blower on / avec ventilateur allumé)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Électrique:

 

 

 

 

* With Maximum horizontal length. / Avec longueur horizontale maximum.

 

 

 

115 V., 1.5 Amps, 60 Hz, 150 Watts

P.4.1-02 Canada Minimum pipe (P.4.1-02 Le canada tuyau minimum) 64.08% NG / 65.42% LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For use with Natural Gas

For use with Propane

 

 

 

 

 

 

 

 

 

 

 

Usage au Gaz Naturel

Usage au Gaz Propane

 

 

 

 

Top Vent: Input Rate on “HI” (BTU/Hr)

 

0-2000’

0-2000’

Bouche Supérieure: Puissance Évaluée à “HI” (BTU/Hr)

 

30,000

30,000

 

Input Rate on “LO” (BTU/Hr)

 

21,000

24,500

 

Puissance Évaluée à “LO” (BTU/Hr)

 

Maximum Output (BTU/Hr)

 

25,000

24,600

 

Puissance Maximum (BTU/Hr)**

 

Main Burner Orifice

 

 

 

.1065 (36DMS)

.0635 (52DMS)

 

Orifice du Brûleur Principal

Rear Vent: (No vertical) Input Rate on “HI” (BTU/Hr)

26,000

26,000

Conduit postérieur: Puissance Évaluée (non vertical) à “HI” (BTU/Hr)

 

Input Rate on “LO” (BTU/Hr)

 

18,000

20,000

 

Puissance Évaluée à “LO” (BTU/Hr)

 

Main Burner Orifice

 

 

 

.0960 (41DMS)

.0595 (53DMS)

 

Orifice du Brûleur Principal

Minimum Inlet Pressure (Inches W.C.)

 

4.5”

11”

Pression Minimum de la Valve (pouces W.C.)

Maximum Inlet Pressure (Inches W.C.)

 

7.0”

14”

Pression Maximum de la Valve (pouces W.C.)

Manifold Pressure on “HI” (Inches W.C.)

 

3.5”

10”

Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)

**Max. Venting, Blower On

 

 

 

 

 

 

 

 

** Ventilation Maximum, Ventilateur Allumé

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: DO NOT OPERATE THIS APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN.

 

 

OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED

SERVICE PERSON.

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTENTION: CET APPAREIL NE DOIT PAS ÊTRE OPÉRÉ SI LA VITRE EST BRISÉE, CRAQUÉE OU ENLEVÉE. LE REMPLACEMENT DU PANNEAU DOIT ÊTRE FAIT PAR UNE PERSONNE

LICENSÉE ET QUALIFIÉE.

 

 

 

 

 

REPLACEMENT

 

 

 

 

 

 

 

 

MINIMUM CLE R NCES TOCOMBUSTIBLES

/ ESPACE MINIMUM AUX COMBUSTIBLES

CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS AY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.

ATTENTION: CHAUD LORQU’IL EST EN OPÉRATION. NE TOUCHEZ PAS. DES BRÛLURES SÉVÈRES PEUVENT EN RÉSULTER. GARDEZ LES ENFANTS, LES VÊTEMENTS, LES MEUBLES, LA GAZOLINE

 

ALTERATION,

ET LES AUTRES LIQUIDES DE VAPEUR INFLAMMABLE ÊLOIGNÉS

WARNING: IMPROPER INSTALLATION, ADJUSTMENT,

 

SERVICE OR AINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION

MANUAL PROVIDED WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFOR ATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

AVERTISSEMENT: UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICE OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES DOMMAGES MATÉRIELS.

RÉFÉREZ-VOUS AU MANUEL D’INFORMATION FOURNI

VEC CET PP REIL. POUR ASSISTANCE OU DES INFORMATIONS SUPPLÉMENTAIRES CONSULTEZ UN INSTALLATEUR

QUALIFIÉ, UNE AGENCE DE SERVICE OU UN FOURNISSEUR DE G Z.

Minimum clearances required from combustible construction for all appliance surfaces. / Espaces minimum exigés de la construction

combustible aux surfaces de l’appareil.

 

 

 

 

F

C

 

 

 

 

G

 

 

 

D

A

A

 

 

 

 

 

B

 

 

 

 

E

C

 

 

A

A

 

 

 

 

 

A.

Side of stove top to side wall

6 in. (152 mm)

 

Du coté du poêle au coté du mur

B.

Rear of stove top to back wall

3 in. (76 mm)

Le contrôle arrière au mur arrière

C.

Corner of stove top to side wall

1 in. (25 mm)

Du Coin du Poêle au coté du mur

D.

Minimum Alcove Height

54 in. (1372 mm)

Hauteur minimum de l'alcôve

E.

Maximum Alcove Depth

36 in. (914 mm)

Profondeur maximum de l'alcôve

F.

Minimum Alcove Width

36 in. (914 mm)

Largeur minimum de l'alcôve

G.

Mantle Clearance from stove top

23 in. (584 mm)

Espace libre du poéle au manteau

HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support the stove without a tipping hazard.

CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.

Date of Manufacture / Date du Manufacturier

 

2008 2009 2010 Jan Feb Mar Apr May Jun

Jul

Aug Sep Oct

Nov Dec

 

 

 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE

Made in U.S.A. / Fait Aux États-Unis

250-7241

 

Serial Number

Barcode

Model Name

Test Lab & Report No.

Manufactured Date

Page 2

Quadra-Fire · Sapphire · 250-7233H

September 1, 2008

 

Page 2
Image 2
Hearth and Home Technologies 839-1460, 839-1390, 839-1440, SAPPH-D-CWL, SAPPH-D-CSB Welcome to the Quadra-Fire Family