Hearth and Home Technologies 839-1390, 839-1440, 839-1460, SAPPH-D-CWL Existing Masonry Chimney

Models: SAPPH-D-CSB SAPPH-D-CWL 839-1460 839-1440 839-1390

1 56
Download 56 pages 20.13 Kb
Page 20
Image 20
4. Existing Masonry Chimney

4. Existing Masonry Chimney

Type A - Up & Out Installations for Top Vent Configurations

Type A - Up & Out Installations for Top Vent ConfigurationsTermination Cap

Top AdapterManual backgroundManual backgroundManual background Flashing

Type B - Hearth Rear Vent Installations for Use With Rear Vent Kit (see Section 12 for conversion kit and venting components.)

Chimney Liner

Manual background Termination Cap

Retro Connector

90º Elbow

Direct Vent PipeManual background

4 in. (102mm) Flex Liner

Co-Axial to

3 in. (76mm)

Co-Linear

Flex Liner

Connector

 

Pipe Length

Optional

Showing two

30 ft. (9m) Sections of Flex Liner

Chimney Liner

Manual background Termination Cap

Co-Axial to Co-Linear

Connector

Pipe Length

Optional

Manual background 30 ft. (9m) of 3 in. (76mm) Flex Liner Exhaust Section

This section of the chimney MUST be sealed

The chimney must be sealed from the 4 ft. (1m) section to termination

Manual backgroundManual backgroundManual backgroundManual background using a smoke shelf or a damper*.

The seal should be 6 in. (152mm) below the end of the 4 ft. (1m) Air Intake section.

4 ft. (1m) of 3 in. (76mm)

Flex Liner

Air Intake Section

Figure 5.23

*In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.