B.Clearances

¨

WARNING

Fire Risk

Comply with all minimum clearances to combustibles as specified.

Framing or finishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).

Failure to comply may cause fire.

Storm Collar

Roof Flashing

2in. min. (51 mm)

(attic)

2 in. (51 mm) min.

Attic

Insulation

Shield

Ceiling Firestop

 

(ceiling)

 

2 in. (51 mm) min.

2 in. (51 mm) min.

Ceiling Firestop

Offset/Return with

 

hanger straps

 

(ceiling)

 

2 in. (51 mm) min.

2 in. (51 mm) min.

 

 

Must have 2 in. (51 mm)

 

minimum clearance

 

0 in. to level

to header

 

of standoffs

 

 

3/4 in. (19 mm) to back

 

of appliance

0 in.

3/4 in. (19 mm) to side of appliance

(except at nailing flanges where it is 1/2 in. [13 mm])

to floor

 

Figure 3.2 Clearances to Combustible Materials

10

Heat & Glo • EM-415/EM-415H • 31317 Rev Q • 10/06

Page 10
Image 10
Hearth and Home Technologies EM-415H owner manual Clearances to Combustible Materials