4

Installation of Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

WARNING

 

 

 

 

Fire Risk

 

 

Sharp Edges

 

 

 

 

Asphyxiation Risk

 

 

• Wear protective gloves and safety glasses

 

 

 

 

Do not draw outside combustion air from:

 

 

during installation.

 

 

 

 

• Wall, floor or ceiling cavity.

 

 

 

 

 

 

 

 

• Enclosed space such as an attic or

 

 

 

 

garage.

 

 

 

 

A. Install the Outside Air Kit

 

• Close proximity to exhaust vents or

 

This fireplace will operate correctly only if adequate ventila-

 

chimneys.

 

 

Fumes or odor may result.

 

tion is provided to allow proper draft to the fireplace system.

 

 

 

 

 

See Section 2.

 

 

 

 

 

 

Using an outside air kit is highly recommended to minimize the effects of negative pressure within the structure. We recommend you utilize the shortest duct run to optimize the performance of the outside air kit. Cold air flow can be mini- mized by putting a small dip in the duct creating a cold air trap. This trap can also help prevent heat build-up and ex- hausting out the intake due to the stack effect. The outside air kit inlet should be positioned in a manner that will not al- low snow, leaves, etc. to block the inlet. In some installations the air duct may need to be run vertically. In such an instal- lation, a 3 ft (.914 m) height difference must be maintained from the top of the uppermost chimney section to the outside combustion air inlet. See Figure 4.2.

See Figure 4.3 for proper placement of outside air inlet.

The outside air kit is installed on the left hand side of the fireplace. See Figure 4.4 for handle location/operation.

CAUTION

Risk of Smoke Spillage

Outside air inlet must be located to prevent blockage from:

Leaves

Snow/ice

Other debris

Blockage may cause combustion air starvation.

 

Flexible Duct

 

 

 

(not supplied)

 

 

 

2 Wire Ties

Outside

 

Outside

 

 

 

Air Collar

 

Air Shield

 

 

 

 

 

Figure 4.1 Outside Air Installation

 

 

 

Heat & Glo • EM-415/EM-415H • 31317 Rev Q • 10/06

13

Page 13
Image 13
Hearth and Home Technologies EM-415 Installation of Fireplace, Install the Outside Air Kit, Risk of Smoke Spillage