Santa Fe Pellet Stove

R

WARNING

Fire Risk

Inspection of Chimney:

Masonry chimney must be in good condition.

Meets minimum standard of NFPA 211

Factory-built chimney must be 6 inch (152mm) UL103 HT.

e. Masonry

Concrete Cap

Fireclay flue

liner with airspace

 

 

Flashing

1 in. (25mm) clearance

 

with firestop

1 in. (25mm) clearance

 

3 in. (76mm) minimum

 

6 in. (152mm)

Sheathing

minimum

 

Cleanout cover

 

Airtight

Non-combustible Hearth Pad

Cleanout Door

 

Figure 15.1

F. Alternate Masonry

Concrete Cap

Fireclay Flue Liner

with airspace

 

 

Flashing

1 in. (25mm) clearance

1 in. (25mm) clearance

with firestop

 

2 in. (51mm) minimum

 

6 in. (152mm)

 

minimum

Sheathing

 

 

Airtight cleanout door

Non-combustible Hearth Pad

 

Figure 15.2