C. Hearth Pad Requirements (UL and ULC)

Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door.

 

L*

K

K

 

M

Figure 9.1

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

*L Exception for Horizontal Installations:

USA INSTALLATIONS: If optional Cast Base is installed use a non-combustible floor protector extending under unit and to the sides, front and back of unit as shown in Floor Protection Diagram. Measure front distance (M) from the surface of the glass door.

If Cast Base is not installed, the non-combustible floor protec- tor must be 1/4 inch (6mm) minimum thickness (“k” value = 0.84).

A non-combustible floor protection extending beneath the flue pipe is recommended with horizontal venting or under the top vent adapter with vertical installation. Figure 9.2.

CANADA INSTALLATIONS: A non-combustible floor pro- tection extending beneath the flue pipe is required with horizontal venting or under the top vent adapter with vertical installation.

Must extend 2 inches (51mm) beyond each side of pipe (shaded area)

Figure 9.2