R

Santa Fe Pellet Stove

B. Clearances to Combustibles (UL and ULC)

A C B

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

38

965

Maximum Alcove Depth

36

914

C

Straight Back Against

Inches

Millimeters

Wall

 

 

 

A

 

Back Wall to Appliance

2

51

B

 

Side Wall to Appliance

6

152

 

 

 

Corner Installation

Inches

Millimeters

C

 

Walls to Appliance

2

51

I

J

C

L

Dimension to Corner

Inches

Millimeters

I

Flue Center Line

8-1/2

217

J

Back of Top Vent Adapter

9-1/8

232

Installations with:

3 to 3 inch Top Vent Adapter and

3 to 6 inch Offset Adapter Kit

F

D

 

E

G

H

H

 

 

G

WARNING

Fire Risk.

Comply with all minimum clearances to combustibles as specified.

Failure to comply may cause house fire.

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Cast Top

6

152

F

Back Wall to Appliance

7

178

 

 

 

Corner Installation

Inches

Millimeters

G

Walls to Appliance

2

51

H

Side Wall to Flue Pipe

3

76

NOTE:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

Page

7001-142D

September 1, 2008

Page 8
Image 8
Hearth and Home Technologies SANTAFE-B1 owner manual Santa Fe Pellet Stove Clearances to Combustibles UL and ULC