Hearth and Home Technologies TRUE-42 Top Vent Horizontal Termination One Elbow, TRUE-50 NG/LP

Models: TRUE-36 TRUE-50 TRUE-42

1 80
Download 80 pages 42.5 Kb
Page 27
Image 27

1.Top Vent - Horizontal Termination One Elbow

WARNING! Risk of Fire!

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

TRUE-36(NG/LP), TRUE-42(NG), and TRUE-50(NG/LP) models require a minimum of 24 inches of vertical venting before attaching any elbow to the appliance.

TRUE-42(LP) model requires a minimum of 36 inches of vertical venting before attaching any elbow to the appliance.

DO NOT attach elbow directly to the appliance.

H1

V1

Figure 7.3

TRUE-36 (NG/LP), TRUE-42 (NG),

TRUE-50 (NG/LP)

V1 Minimum

H1

Maximum

2 ft

610 mm

7 in*

 

178 mm

 

 

 

 

 

3 ft

914 mm

2 ft

 

610 mm

4 ft

1.2 m

4 ft

 

1.2 m

5 ft

1.5 m

9 ft

 

2.7 m

 

 

 

 

 

6 ft

1.8 m

12 ft

 

3.7 m

7 ft

2.1 m

14 ft

 

4.3 m

10 ft

3.0 m

20 ft

 

6.1 m

 

 

 

 

 

20 ft

6.1 m

40 ft

 

12.2 m

 

 

 

 

 

After V1= 6 ft then H1 = 2 x V ft Maximum

V1 + H1 = 60 ft Maximum

*when used with approved termination caps

TRUE-42 (LP)

V1 Minimum

H1 Maximum

3 ft

914 mm

10 in.

254 mm

4 ft

1.2 m

4 ft

1.2 m

 

 

 

 

5 ft

1.5 m

9 ft

2.7 m

 

 

 

 

6 ft

1.8 m

12 ft

3.7 m

7 ft

2.1 m

14 ft

4.3 m

10 ft

3.0 m

20 ft

6.1 m

 

 

 

 

20 ft

6.1 m

40 ft

12.2 m

 

 

 

 

After V1= 6 ft then H1 = 2 x V ft Maximum

V1 + H1 = 60 ft Maximum

*when used with approved termination caps

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

27

Page 27
Image 27
Hearth and Home Technologies Top Vent Horizontal Termination One Elbow, TRUE-36 NG/LP, TRUE-42 NG, TRUE-50 NG/LP