Hearth and Home Technologies TRUE-50, TRUE-42 Top Vent Horizontal Termination Three Elbows

Models: TRUE-36 TRUE-50 TRUE-42

1 80
Download 80 pages 42.5 Kb
Page 29
Image 29

1. Top Vent - Horizontal Termination - (continued)

Three Elbows

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

WARNING! Risk of Fire!

TRUE-36(NG/LP), TRUE-42(NG/LP) and TRUE-50 (NG/LP) models require a minimum of 24 inches of vertical venting before attaching any elbow to the appliance.

DO NOT attach elbow directly to the appliance.

H2

V2

H1

V1

TRUE-36 (NG/LP), TRUE-42 (NG/LP), TRUE-50 (NG/LP)

 

V1

 

H1

V2

H2

2 ft

610 mm

7 in

178 mm

*

H2 Max = 2 X V2

3 ft

914 mm

2 ft

610 mm

*

H2 Max = 2 X V2

4 ft

1.2 m

4 ft

1.2 m

*

H2 Max = 2 X V2

5 ft

1.5 m

9 ft

2.7 m

*

H2 Max = 2 X V2

6 ft

1.8 m

12 ft

3.7 m

*

H2 Max = 2 X V2

7 ft

2.1 m

14 ft

4.3 m

*

H2 Max = 2 X V2

10 ft

3.0 m

20 ft

6.1 m

*

H2 Max = 2 X V2

V1 + H1 must be adhered to.

* V2 has no specific restrictions EXCEPT,

Ht max = 2 x Vt and Vtotal + Htotal cannot exceed 60 ft Maximum

Figure 7.5

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

29

Page 29
Image 29
Hearth and Home Technologies TRUE-50, TRUE-42, TRUE-36 owner manual Top Vent Horizontal Termination Three Elbows