Hearth and Home Technologies TRUE-36 Electrical Service and Repair Junction Box Installation

Models: TRUE-36 TRUE-50 TRUE-42

1 80
Download 80 pages 42.5 Kb
Page 46
Image 46

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.

E. Junction Box Installation

If the box is being wired from the INSIDE of the appliance:

The junction box is accessible through the front left column if finishing materials have not been installed. The junction box is also accessible through the firebox access panel. See Figure 12.2.

Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to dis- engage it from the outer shell. See Figure 12.3.

Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 12.3

Make all necessary wire connections to the junction box/ receptacle and reattach the junction box/receptacle to the outer shell.

NOTICE: DO NOT wire 110 VAC to wall switch.

Romex

 

Connector

WHT

 

 

BLK

 

WHT

14/2WG

BLK

 

GRN wire inside box

Copper ground attached to GRN screw with GRN wire

Figure 12.3 Junction Box Detail

 

ACCESS THROUGH LEFT COLUMN

ACCESS THROUGH FIREBOX

 

(Prior to installation of non-combustible board)

(After installation of non-combustible board)

 

 

GASKET

 

 

COVER

Figure 12.2 Junction Box Access

 

46

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

Page 46
Image 46
Hearth and Home Technologies TRUE-36, TRUE-42, TRUE-50 owner manual Electrical Service and Repair Junction Box Installation