F. Install Vertical Termination Cap

Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section.

Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe (see Figure 10.13).

TERMINATION CAP

(1 of 3)

STORM

COLLAR

SCREWS

CAULK

Figure 10.13

G.Heat Shield Requirements for Horizontal Termination

WARNING! Risk of Fire! To prevent overheating and fire, heat shields must extend through the entire wall thick- ness.

DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap shown in Figure 10.14.

Heat shields must overlap 1-1/2 in. (38 mm) mini- mum.

There are two sections of the heat shield. One section is factory-attached to the wall shield firestop. The other section is factory-attached to the cap. See Figure 10.14.

If the wall thickness does not allow the required 1-1/2 in. (38 mm) heat shield overlap when installed, an extended heat shield must be used.

If the wall thickness is less than 4 in./102 mm (DVP), the heat shields on the cap and wall shield firestop must be trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST be maintained.

Use an extended heat shield if the finished wall thickness is greater than 7-1/4 in. (184 mm).

The extended heat shield may need to be cut to length maintaining sufficient length for a 1-1/2 in. (38 mm) overlap between heat shields.

Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the back of this manual.

Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section.

Important Notice: Heat shields may not be field constructed.

H. Install Horizontal Termination Cap

WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent.

1-1/2 (38 mm) minimum overlap of flue telescoping section is required.

Failure to maintain overlap may cause overheating and fire.

Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base.

Flash and seal as appropriate for siding material at outside edges of cap.

When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149installation codes and refer to Section 6 of this manual.

CAUTION! Risk of Burns! Local codes may require in- stallation of a cap shield to prevent anything or anyone from touching the hot cap.

NOTICE: For certain exposures which require superior resistance to wind-driven rain penetration, a flashing kit is available. When penetrating a brick wall, a brick extension kit is available for framing the brick.

Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall.

HEAT SHIELD OR

HEAT SHIELD

EXTENDED

1-1/2 IN. (38 MM) MIN.

HEAT SHIELD

OVERLAP

WALL SHIELD

 

FIRESTOP

 

SLIP SECTION

 

CAN BE EXTENDED

 

INNER VENT

SHEATHING

OUTER VENT

 

INTERIOR

EXTERIOR

VENT DEPTH FROM BACK OF APPLIANCE TO

 

OUTSIDE SURFACE OF EXTERIOR WALL

 

(SEE CHART BELOW)

 

Figure 10.14 Venting through the wall

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

43

Page 43
Image 43
Hearth and Home Technologies TRUE-36 Install Vertical Termination Cap, Heat Shield Requirements for Horizontal Termination

TRUE-36, TRUE-50, TRUE-42 specifications

Hearth and Home Technologies offers a range of innovative fireplaces, and the TRUE series stands out for its exceptional design and advanced technology. The TRUE-42, TRUE-50, and TRUE-36 models are popular choices among homeowners looking for contemporary aesthetics combined with efficient heating solutions.

The TRUE-42 fireplace is designed for modern living spaces, offering a clear view of the flames from multiple angles. Its sleek, linear design allows it to be seamlessly incorporated into any room. One of its main features is the expansive glass front that enhances the visuals of the fire while promoting maximum heat output. With an input range of 27,000 to 50,000 BTUs, this model excels at warming larger spaces efficiently. Additionally, it includes adjustable flame height and various log or ember bed options, allowing users to customize their fire experience.

The TRUE-50 model takes the design and performance up a notch, providing an even larger viewing area with its 50-inch glass front. This fireplace is perfect for grand living rooms or commercial spaces, where ambiance and style are a priority. It features innovative technology such as auto ignition and an optional remote control, giving homeowners the flexibility to control the fire with ease. The TRUE-50 also allows for venting options, making it adaptable to a range of installation requirements, thus enhancing its versatility in different home settings.

Lastly, the TRUE-36 serves as a more compact option without sacrificing aesthetic appeal. It delivers the same stunning flame effect and high-efficiency heating as its larger counterparts, making it suitable for smaller rooms or cozy spaces. The TRUE-36 is designed to create a focal point in any room, featuring modern controls and customizable flame options.

All TRUE fireplaces boast advanced technologies like the Intellifire ignition system, which enhances safety and convenience by ensuring reliable lighting every time. Energy efficiency is a priority as well, with these models meeting stringent environmental standards, thereby providing heat without excessive emissions.

In summary, Hearth and Home Technologies’ TRUE series, including the TRUE-42, TRUE-50, and TRUE-36, offers cutting-edge design and performance. These models exemplify modern fireplace innovation, blending style, efficiency, and technological advancement, making them an excellent choice for any home or commercial space looking to enhance its ambiance.