D. Install Metal Roof Flashing

See minimum vent heights for various pitched roofs (Figure 10.9) to determine the length of pipe to extend through the roof.

Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 10.10.

 

 

HORIZONTAL

 

 

OVERHANG

2 FT.

20 INCHES MIN.

VERTICAL

MIN.

 

 

WALL

 

LOWEST

 

 

 

DISCHARGE

 

 

OPENING

 

GAS DIRECT VENT

 

 

TERMINATION CAP

 

 

 

 

X

 

 

12

 

 

ROOF PITCH

 

 

IS X/ 12

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

TO LOWEST DISCHARGE OPENING

Roof Pitch

 

H (Min.) Ft.

Flat to 6/12........................................1.0*

Over 6/12 to 7/12............................1.25*

Over 7/12 to 8/12..............................1.5*

Over 8/12 to 9/12..............................2.0*

Over 9/12 to 10/12............................. 2.5

Over 10/12 to 11/12 ......................... 3.25

Over 11/12 to 12/12 ........................... 4.0

Over 12/12 to 14/12........................... 5.0

Over 14/12 to 16/12........................... 6.0

Over 16/12 to 18/12........................... 7.0

Over 18/12 to 20/12........................... 7.5

Over 20/12 to 21/12........................... 8.0

* 3 foot minimum in snow regions

Figure 10.9 Minimum Height From Roof To Lowest Discharge

Opening

 

 

NOTICE: Failure to properly caulk the roof flashing and pipe seams may permit entry of water.

Caulk the gap between the roof flashing and the outside diameter of the pipe.

Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.10.

Caulk the overlap seam of any exposed pipe sections that are located above the roof line.

CAULK

Figure 10.10

E. Assemble and Install Storm Collar

CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Connect both halves of the storm collar with two screws (see Figure 10.11).

Wrap the storm collar around the exposed pipe section closest to the roof and align brackets. Insert a bolt (provided) through the brackets and tighten the nut to complete the storm collar assembly. Make sure the collar is tight against the pipe section.

Slide the assembled storm collar down the pipe section until it rests on the roof flashing (see Figure 10.12).

Caulk around the top of the storm collar (see Figure 10.13).

Figure 10.11 Assembling the Storm Collar

Figure 10.12 Assembling the Storm Collar Around the Pipe

42

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

Page 42
Image 42
Hearth and Home Technologies TRUE-42, TRUE-36, TRUE-50 Install Metal Roof Flashing, Assemble and Install Storm Collar

TRUE-36, TRUE-50, TRUE-42 specifications

Hearth and Home Technologies offers a range of innovative fireplaces, and the TRUE series stands out for its exceptional design and advanced technology. The TRUE-42, TRUE-50, and TRUE-36 models are popular choices among homeowners looking for contemporary aesthetics combined with efficient heating solutions.

The TRUE-42 fireplace is designed for modern living spaces, offering a clear view of the flames from multiple angles. Its sleek, linear design allows it to be seamlessly incorporated into any room. One of its main features is the expansive glass front that enhances the visuals of the fire while promoting maximum heat output. With an input range of 27,000 to 50,000 BTUs, this model excels at warming larger spaces efficiently. Additionally, it includes adjustable flame height and various log or ember bed options, allowing users to customize their fire experience.

The TRUE-50 model takes the design and performance up a notch, providing an even larger viewing area with its 50-inch glass front. This fireplace is perfect for grand living rooms or commercial spaces, where ambiance and style are a priority. It features innovative technology such as auto ignition and an optional remote control, giving homeowners the flexibility to control the fire with ease. The TRUE-50 also allows for venting options, making it adaptable to a range of installation requirements, thus enhancing its versatility in different home settings.

Lastly, the TRUE-36 serves as a more compact option without sacrificing aesthetic appeal. It delivers the same stunning flame effect and high-efficiency heating as its larger counterparts, making it suitable for smaller rooms or cozy spaces. The TRUE-36 is designed to create a focal point in any room, featuring modern controls and customizable flame options.

All TRUE fireplaces boast advanced technologies like the Intellifire ignition system, which enhances safety and convenience by ensuring reliable lighting every time. Energy efficiency is a priority as well, with these models meeting stringent environmental standards, thereby providing heat without excessive emissions.

In summary, Hearth and Home Technologies’ TRUE series, including the TRUE-42, TRUE-50, and TRUE-36, offers cutting-edge design and performance. These models exemplify modern fireplace innovation, blending style, efficiency, and technological advancement, making them an excellent choice for any home or commercial space looking to enhance its ambiance.