V2

V1

H

Figure 5.8

Natural Gas • Two 900 Elbows System

V1 Min.

 

H Max.

31 cm

 

93 cm

61 cm

 

1.8 M

91 cm

 

2.7 M

1.2 M

 

3.6 M

1.5 M

 

4.5 M

V1+V2+H = Max 11.4M

H Max = 4.5M

Propane • Two 900 Elbows System

V1 Min.

 

H Max.

31 cm

 

62 cm

61 cm

 

1.2 M

91 cm

 

1.8 M

1.2 M

 

2.4 M

1.5 M

 

3.0 M

V1+V2+H = Max 11.4M

H Max = 3.0M

Butane • Two 900 Elbows System

V1 Min.

 

H Max.

31 cm

 

31 cm

61 cm

 

61 cm

92 cm

 

92 cm

1.2 M

 

1.2 M

1.5 M

 

1.5 M

V1+V2+H = Max 10 M

H Max = 1.0 M

Natural Gas • Two 900 Elbows System

 

V Min.

H1+H2 Max.

 

61 cm

1.6 M

 

91 cm

2.4 M

H2

1.2 M

3.2 M

 

1.5 M

4.0 M

H1

V+H1+H2 = Max 11.4M

H1+H2 = Max 4.0M

Propane • Two 900 Elbows System

 

V Min.

H1+H2 Max.

 

61 cm

1.0 M

 

91 cm

1.5 M

V

1.2 M

2.0 M

 

1.5 M

2.6 M

 

V+H1+H2 = Max 11.4M

H1+H2 = Max 2.6M

 

Butane • Two 900 Elbows System

 

V1 Min.

H1+H2 Max.

 

61 cm

42 cm

 

92 cm

64 cm

 

1.2 M

.8 M

 

1.5 M

1.0 M

 

V+H1+H2 = Max 10 M

H1+H2 = Max 1.5 M

 