Heat & Glo LifeStyle 8000TRD manual Wiring the Fireplace, Optional Accessories

Models: 8000TRD

1 33
Download 33 pages 3.26 Kb
Page 28
Image 28

3/16” PIGGYBACK CONNECTOR

BLACK S2

REMOTE SWITCH

 

PIGTAIL

ON

 

OFF

 

 

WHITE T2

ON/OFF

 

SWITCH

GAS VALUE

RED T1

 

 

 

 

THERMOPILE

 

THERMOCOUPLE

 

OPTIONAL WALL SWITCH,

 

BLACK S1

 

THERMOSTAT OR REMOTE

Figure 37. Standing Pilot Ignition Wiring Diagram

 

Step 8. Wiring the Fireplace

Optional Accessories

NOTE: Electrical wiring must be installed by a licensed

Optional fan and remote control kits require that 110-120

electrician.

VAC be wired to the factory installed junction box before

CAUTION: DISCONNECT REMOTE CONTROLS IF AB-

the fireplace is permanently installed.

Wall Switch

SENT FOR EXTENDED TIME PERIODS TO PREVENT

ACCIDENTAL FIREPLACE OPERATION.

Position the wall switch in the desired position on a wall.

For Standing Pilot Ignition Wiring

Run a maximum of 25 feet (7.8 m) or less length of 18

A.W.G. minimum wire and connect it to the fireplace ON/

 

 

 

Appliance Requirements

OFF switch pigtails.

This appliance DOES NOT require 110-120 VAC to operate.

 

 

!

WARNING: DO NOT CONNECT 110-120 VAC

 

 

 

 

TO THE WALL SWITCH OR THE CONTROL

 

 

WARNING: DO NOT CONNECT 110-120 VAC

 

 

!

 

 

VALVE WILL BE DESTROYED.

 

TO THE GAS CONTROL VALVE OR THE AP-

 

 

 

 

 

 

 

 

PLIANCE WILL MALFUNCTION AND THE

 

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-

 

VALVE WILL BE DESTROYED.

 

TION WHEN SERVICING CONTROLS. WIRING ERRORS

 

 

 

CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

 

 

 

 

 

 

VERIFY PROPER OPERATION AFTER SERVICING.

BLK

VARIABLE SPEED CONTROL

BLK

JUNCTION BOX

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105OC RATED WIRE.

BLK

BLK

TEMPERATURE SENSOR SWITCH

BLK

 

 

BLK

BLK

 

WHT

WHT

BLK

 

GROUND

 

GRN

 

BLK

WHT

110-120 VAC

 

BLOWER RECEPTACLE

 

BLOWER

JUNCTION BOX

TEMPERATURE

SENSOR SWITCH

FAN

SPEED CONTROL (RHEOSTAT)

Figure 38. Fan Wiring Diagram

28