4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Fig- ure 9).

5. Reinstall the Exhaust Shield.

1 2 3 4 5

SETTINGS

1 2 3 4 5

Figure 9

3.Match the amount of vertical you have in the sys- tem with the chart to find the appropriate position to set the Flue Restrictor.

 

 

- CHART -

 

 

Vertical

Top Vent

Top Vent

 

Rear Vent

Rear Vent

NG

LP

 

NG

LP

 

 

4'

1-1

No

 

No

No

Restrictor

 

Restrictor

Restrictor

 

 

 

8'

2-2

1-2

 

1-1

No

 

Restrictor

 

 

 

 

 

15'

3-3

3-2

 

2-2

1-2

 

 

 

 

 

 

20'

3-4

3-3

 

3-3

2-3

 

 

 

 

 

 

25'

3-4

3-3

 

3-3

2-3

 

 

 

 

 

 

30'

4-4

3-4

 

3-4

3-3

 

 

 

 

 

 

35'

4-4

3-4

 

3-4

3-3

 

 

 

 

 

 

40'

5-4

4-4

 

4-4

3-4

 

 

 

 

 

 

HORIZONTAL VENTING

Kit No.

H Max. Run

DVK-01D

 

DVK-01TRD

24" (610 mm)

H

90-DEGREE ELBOWS

45-DEGREE

ELBOW

NOTE: 8000TRD model is tested and approved to use 45° elbows in corner installations. However, 90° elbows will result in better per- formance.