Venting with 3 elbows

1. Top Vent - Horizontal Termination - (continued)

Top Vent - Horizontal Termination

Venting with 3 elbows

SLR-C

V1 Minimum

H1 + H2 Maximum

V2

V1 + V2 Minimum

90° Elbow

6 ft.

1.8 m

*

*

1 ft.

305 mm

10 ft.

3.0 m

*

*

2 ft.

610 mm

12 ft.

3.7 m

*

*

3 ft.

914 mm

14 ft.

4.3 m

*

*

H1 + H2 MAX. =14 ft. (4.3 m)

V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

*No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12.2 m)

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

H2

CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS termination caps are not approved for use with pro- pane (LP) fuel. May lead to elevated glass temper- ature that may cause tempered glass breakage.

V2

H1

V1

Figure 7.6