Heat & Glo LifeStyle SLR-C (COSMO) Top Vent - Vertical Termination, Venting with 2 elbows, Slr-C

Models: SLR-C (COSMO)

1 71
Download 71 pages 48.08 Kb
Page 30
Image 30
Top Vent - Vertical Termination

Top Vent - Vertical Termination

Venting with 2 elbows

SLR-C

V1 Minimum

H Maximum

V2

V1 + V2 Minimum

 

90° Elbow

2 ft.

610 mm

*

*

1 ft,

 

152 mm

3 ft.

914 mm

*

*

2 ft.

 

457 mm

5 ft.

1.5 m

*

*

3 ft.

 

914 mm

7 ft.

2.1 m

*

*

4 ft.

 

1.1 m

15 ft.

4.6 m

*

*

H MAX. =15 ft. (4.6 m)

V1 + V2 + H MAX. = 40 ft. (12.2 m)

* No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12.2 m)

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

V2

H1

V1

Figure 7.11

30

Heat & Glo • SLR-C2292-900 Rev. D • 8/12

Page 30
Image 30
Heat & Glo LifeStyle SLR-C (COSMO) Top Vent - Vertical Termination, Venting with 2 elbows, Slr-C, V1 Minimum, H Maximum