12 Electrical Information
A. Wiring Requirements
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
Code CSA C22.1.
•Wire the appliance junction box to
•A
•Low voltage and 110 VAC voltage cannot be shared within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.
B. IntelliFire Ignition System Wiring
•Wire the appliance junction box to 110 VAC for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.
•Refer to Figure 12.2, IntelliFire Pilot Ignition (IPI) Wiring Diagram.
•This appliance is equipped with an IntelliFire control valve which operates on a 3 volt system.
•Plug the
box to supply power to the unit OR install two D cell batteries (not included) into the battery pack before use.
NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur.
C. Optional Accessories Requirements
•This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.
NOTE: Install optional remote receiver adjacent to battery pack. See Figure 11.5.
Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.
Optional Remote Control Receiver and Battery Pack Location
Batteries are to be installed only when battery power is required. Because of the limited accessibility to valve cavity, the position of the battery pack, IPI control module, and optionalremote control receiver locations must be installed as shown in Figure 12.1.
The battery pack, control module, and remote control receiver can be accessed through the air space between the firebox front and the
The battery pack is attached with velcro to the inside of the lower cover panel. The IPI control module and the remote control receiver are placed on the firebox bottom.
GAS VALVE
| CONTROL |
|
CONTROL MODULE GROUND | MODULE | DC ADAPTER |
| ||
|
|
BATTERY
PACK
Figure 12.1 Valve Cavity