GLASS SPECIFICATIONS:
LARGE GLASS: TEMPERED
SMALL GLASS: TEMPERED
This statement is in compliance with CPSC 16 CFR Section 1201.5 “Certification and labeling requirements” which refers to 15 USC 2063 stating “…Such certifi- cate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the prod- uct is delivered.”
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.
•Save the remaining ember materials for use during fireplace ser- vicing. The bag of em- bers provided is suffi- cient for 3 to 5 applica- tions.
•Replace the wing nut, glass clips and screws.
•Replace the glass door and a front trim door on the unit.
•Hand tighten the wing nut.
Placing the Ember Material
Ember material is shipped with this gas fireplace. The bag labeled Golden Ember
•Remove the wing nuts and glass clips or tension springs around the glass door. Remove the glass door from the unit.
•Place dime size pieces of ember material about 1/2 inch apart near port holes in burner top. Do NOT press embers into burner ports. Cover the top of the burner with a single layer of ember material. For best perfor- mance do NOT place embers on the ports at the rear of the burner.
Figure 15. Placement of the Ember Material
28