Heat Controller DMC09SB-0 ConnectionOfTheCable, Dismount caps on the conduit panel, Installation

Models: DMH12SB-0 DMH18SB-1 DMC24SB-1 DMH24SB-1 DMH09SB-0 DMC09SB-0 DMC12SB-0 DMC18SB-1

1 73
Download 73 pages 60.73 Kb
Page 26
Image 26
ConnectionOfTheCable

Installation

2.Dismount caps on the conduit panel.Wiring DiagramConnection5.Ground the unit in accordance with local codes.Of7.Use lock nuts to secure the conduit tubes.The1.shows field wiring.Cable2.Separately wire the high and low voltage line.(For example, Type SJOW)•Every wire must be connected firmly.Power SupplyOutdoor unit26Room Air ConditionerManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

1.Remove the cover control from the unit by loosening the 3 screws.

2.Dismount caps on the conduit panel.

3.Temporarily mount the conduit tubes on the conduit panel.

4.Properly connect both the power supply and low voltage lines to the corresponding ter- minals on the terminal block.

Wiring Diagram

Connecting cable(Low voltage) b

Indoor Unit

Outdoor Unit

Terminal

Terminal

(4P)

(6P)

11

22

3

3

Power supply

a

 

 

44

L1* 5

L2 6

5.Ground the unit in accordance with local codes.

6.Be sure to size each wire allowing several inches longer than the required length for wiring.

7.Use lock nuts to secure the conduit tubes.

NOTICE

Connector trade size for this unit is 1/2" for instructions on connecting depending on the wire type you are using.

GTo branch circuit

Manual background Ground

*L1 is neutral for 115V models.

NOTICE

1.shows field wiring.
2.Separately wire the high and low voltage line.

3.Use heat-proof electrical wiring capable of withstanding temperatures up to 167°F(75°C).

4.Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and outdoor unit.

(For example, Type SJOW)

Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and wiring method, etc).

Every wire must be connected firmly.

No wire should be allowed to touch refrig- erant tubing, the compressor or any mov- ing parts.

Power Supply

Model

Power source

 

AWG(MIN.)

 

MOP(MAXIMUN OVER-

 

 

 

 

CURRENT PROTECTION)

 

AWG

MCA

 

9k Cooling

1ø, 115V

18

8.6

15

9k Heating

1ø, 115V

14

14.3

20

12k

Cooling

1ø, 115V

14

14.3

20

12k

Heating

1ø, 115V

14

14.3

20

18k

Cooling

1ø, 230/208V

14

13.6

20

18k

Heating

1ø, 230/208V

14(12)

17.7

30

24k

Cooling

1ø, 230/208V

14(12)

17.7

30

24k

Heating

1ø, 230/208V

14(12)

17.7

30

Outdoor unit

Terminal block

Over 5mm Manual background (0.2") Manual background

Cover control

Conduit panel

Manual backgroundManual backgroundManual background Connecting Manual backgroundcable

Power supply cord

26Room Air Conditioner

Page 26
Image 26
Heat Controller DMC09SB-0 ConnectionOfTheCable, Dismount caps on the conduit panel, 26Room Air Conditioner, Installation