Heat Controller DMC09SB-0, DMC18SB-1 FunctionofControls, Display, Cooling Mode Operation

Models: DMH12SB-0 DMH18SB-1 DMC24SB-1 DMH24SB-1 DMH09SB-0 DMC09SB-0 DMC12SB-0 DMC18SB-1

1 73
Download 73 pages 60.73 Kb
Page 34
Image 34
Operation

Operation

Operation

FunctionofControls• DISPLAYFunctionOperation IndicatorofTimer IndicatorControlsComp. Running IncidatorDefrost Indicator■Cooling Mode Operation■Healthy Dehumidification Mode34Room Air ConditionerManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

• DISPLAY

1) C/O Model

Operation Indicator

ON while in appliance operation, OFF while in appliance pause.

Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)

Timer Indicator

• ON while in timer mode (on/off), OFF when timer mode is completed or canceled.

Comp. Running Incidator

While in appliance operation, ON while in outdoor unit compressor running, OFF while in compres- sor off.

2)H/P Model

Operation Indicator

ON while in appliance operation, OFF while in appliance pause.

Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)

Timer Indicator

• ON while in timer mode (on/off), OFF when timer mode is completed or canceled.

Defrost Indicator

OFF except when hot start during heating mode operation or while in defrost control.

Cooling Mode Operation

When the intake air temperature reaches 0.5°C(0.9°F) below the setting temp, the compressor and the outdoor fan stop.

When it reaches 0.5°C(0.9°F) above the setting temp, they start to operate again.

Compressor ON Temp

Setting Temp+0.5°C(0.9°F)

Compressor OFF Temp

Setting Temp-0.5°C(0.9°F)

While in compressor running, operating with the airflow speed set by the remote control. While in compressor not running, operating with the low airflow speed regardless of the setting.

Healthy Dehumidification Mode

When the dehumidification operation input by the remote control is received, the intake air tempera- ture is detected and the setting temp is automatically set according to the intake air temperature.

26°C(78.8°F) Intake Air Temp25°C(77°F)

24°C(75.2°F) Intake Air Temp<26°C(78.8°F) Intake Air Temp-1°C(1.8°F)

18°C(64.4°F) Intake Air Temp<24°C(75.2°F)

Intake Air Temp-0.5°C(0.9°F)

Intake Air Temp<18°C(64.4°F)

18°C(64.4°F)