Heatiator CD4236ILR-C, CD4236IR-C, CD4842ILR-C, CD4842IR-C Logs/Grate and Valve Assembly Removal

Models: CD4842IR-C CD4236ILR-C CD4842ILR-C CD4236IR-C

1 73
Download 73 pages 17.75 Kb
Page 16
Image 16

C. Logs/Grate and Valve Assembly Removal

It may become necessary to remove the logs/grate and valve assembly. This task should be performed by a quali- fied service technician. The base pan does not need to be removed to service the burner assembly.

1.Remove the two top logs from the log/grate assembly. These logs are not secured to the assembly with screws. See Figure 3.2.

4.The standard metal refractory will have to be removed in order to access the valve assembly. This is done by removing 8 screws (10 screws for CD4842IR-C model). There are 4 screws per side panel, Figure 3.5 shows the 2 screws on the bottom of panels and Figure 3.6 shows the 2 screws on the top of the panels. The 2 other screws for CD4842IR-C models are located in back wall of firebox as shown in Figure 3.7. One is up by exhaust baffle and the other is behind logs and near fireplace bottom.

Figure 3.2 Remove Top Two Logs

2.Remove screw from each tab at the front of the log/grate assembly that secures the assembly to the base pan. See Figure 3.3

Figure 3.3 Remove Screws from Front Tab

3.Remove screws from log tabs on both ends of the rear log and remove the log. See Figure 3.4.

Figure 3.5 Bottom Screws For Metal Refractory

Figure 3.6 Top Screws For Metal Refractory

2 EXTRA SCREWS TO BE REMOVED FOR CD4842IR-C

Figure 3.7 CD4842IR-C Extra Metal Refractory Screws

Figure 3.4 Remove Screws from Log Tabs

16

Heatilator • CD4236IR-C, CD4842IR-C2207-900 Rev. J • 11/11

Page 16
Image 16
Heatiator CD4236ILR-C, CD4236IR-C Logs/Grate and Valve Assembly Removal, Extra Screws to be Removed for CD4842IR-C