12 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (IntelliFire PlusTM ignition).

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

B. IntelliFire PlusTM Ignition System Wiring

Wire the appliance junction box to 110 VAC for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 12.1, IPI Wiring Diagram.

This appliance is equipped with an IntelliFire PlusTM control valve which operates on a 6 volt system.

Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries (not included) into the battery pack before use.

C. Optional Accessories Requirements

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.

Hearth & Home Technologies recommends that Intel- liFire PlusTM wireless controls be used for their features and functionality with the IntelliFire PlusTM ignition sys- tem.

 

 

FLAME

IGNITOR

 

 

 

 

 

 

 

SENSE

 

 

 

 

 

 

TO JUNCTION

 

 

 

 

 

 

 

 

BOX (110V)

 

 

 

 

 

 

 

 

 

MODULE

 

 

 

 

 

 

 

FLAME

 

 

 

 

 

 

 

 

MODULATION

 

 

 

 

 

RC100

RC200

 

 

 

 

 

 

 

 

 

 

 

 

 

(OPTIONAL WALL CONTROLS)

ORANGE

GREEN

 

 

 

BATTERY PACK

 

 

 

(PILOT)

(MAIN)

 

 

 

 

 

 

 

 

 

6V DC

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

THERMOSTAT WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSEMBLY / WALL

 

 

BROWN

 

 

 

 

SWITCH WIRE

 

 

 

GROUND

 

 

 

 

 

 

Figure 12.1 IPI Wiring Diagram

 

 

 

 

 

 

 

 

Heatilator

CD4236IR-C, CD4842IR-C

2207-900 Rev. J

11/11

51

Page 51
Image 51
Heatiator CD4842IR-C, CD4236ILR-C Electrical Information, Wiring Requirements, IntelliFire PlusTM Ignition System Wiring