13 Finishing

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.)

Combustible Mantels

Note: All

 

 

measurements

 

in inches.

TO CEILING

 

 

 

 

18

 

12

 

 

11

 

 

10

32

 

9

 

25

 

8

 

7

19

 

6

 

18

 

5

4

17

 

16

3

15

 

 

 

 

14

 

 

13

 

2-1/2

12

 

11

 

 

 

 

10

 

5

 

 

 

MEASUREMENTS FROM

 

TOP EDGE OF THE OPENING

Figure 13.1 Minimum Vertical and Maximum

Horizontal Dimensions

 

Mantel Legs or Wall Projections

Top of

 

Appliance

Drywall

 

A

B

Mantel Leg or

Perpendicular Wall

A1 in. (25 mm) min. to perpendicular wall

B3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall

Figure 13.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening)

B. Facing Material

Metal front faces may be covered with non-combustible materials only.

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

Seal joints between the finished wall and appliance top and sides using a 300 ºF minimum sealant. Refer to Figure 13.3.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

B

FACTORY-INSTALLED NON-COMBUSTIBLE BOARD

DO NOT REMOVE

A

 

 

A

B

 

 

 

 

CD4236

inches

39-3/4

41

millimeters

1010

1041

 

CD4842

inches

41-3/4

48

millimeters

1060

1219

 

Figure 13.3 Noncombustible Facing Diagram

Heatilator • CD4236IR-C, CD4842IR-C2207-900 Rev. J • 11/11

53

Page 53
Image 53
Heatiator CD4236IR-C, CD4236ILR-C, CD4842ILR-C, CD4842IR-C owner manual Finishing, Facing Material, Combustible Mantels