D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).

Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.

Framing across the top of fireplace must be above top standoffs.

54 5/8 in. (1387 mm) *

22 1/2 in.

(572 mm) *

*If the interior of the chase will be drywalled, add the thick- ness to this measurement.

REQUIRED!

2 in. (51 mm) minimum air space

clearance around chimney

18 in. (457 mm)

minimum distance

from wall to

fireplace opening.

1/2 in. (13 mm) Clearance

Figure 6.4 Framing the Fireplace

1/2 in.

Drywall

42-1/2 in.

(1080 mm)

22 1/2 in.

(572 mm) *

1/2 in. (13 mm) Clearance

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

21

Page 21
Image 21
Heatiator CL36D, CR36D owner manual Frame the Fireplace, Required