dS: defrost system (computation); dF=digifrost Feature; | |
Continued | defrost start time based on total compressor running time |
rt=real time; defrost start frequency, based on real time
dI: defrost interval; defrost frequency in hours, based on the selection of “dS”
dE: defrost endurance; total (maximum) length of a defrost cycle, expressed in minutes. (1...99 range)
dL: display lock; temperature display is locked during a defrost cycle (0...31 range)
“n”=no (readout continues to display the actual tempera- ture, even during a defrost cycle
“y”=yes (readout is locked)
dr: display
locked and does not change during this cycle; “dF”=during the defrost “dF” is displayed.
do: defrost at power on; selects whether or not, the system goes through the defrost cycle at
“n”=no; “y”=yes
dd: defrost delay at power on; delay of defrost cycle, in minutes (0...99 range)
Error Code “E1”
This is the only error code in these controls. It indicates a tempera- ture sensor failure, such as, a shorted sensor, a sensor break, or absence of sensor.