Calibrate the flags

CHAPTER 5

Maintenance and Troubleshooting

5.Connect one end of a harness to a flag of the dimmer motor and the other to the corresponding header on the 2-phase board (see page 45). You can connect and home one flag or a pair of flags at the same time.

Calibrate the flags

6.Power up the fixture. Unlock the Menu system by pressing Menu vertical flag button for a few seconds until the display goes to the 2-line format.

7.Use the left and right arrows adjustmentManual background to scroll to the Test option. Press Enter Manual background to select.

8.Use the up and down Manual background arrows to scroll to SETUP MOTORS. Press Enter Manual background to select. Use Manual background arrows to scroll to YES and press Enter Manual background to select. Flags will energize against the standoffs.

9.Using a 2 mm hex key, loosen the set screw at the base of the flag.

10.Adjust each flag vertically to the tickmark on the inside

standoff.

Tick marks for

 

 

vertical flag

 

adjustment

SHOWGUN® User Manual