Appendix: Installation
2. Location
WARNING: Maintain the required space around the
appliance to prevent overheat.
The area for installation of the appliance should not be in an area with the following:
Di rect sunlight
H eat resource
Inflammable gas
Thick oil fog
The appliance should be installed in an area,
Where the inside space can be evenly conditioned, or
Which is strong enough for the appliance, or,
Having the shortest distance for the copper tubes and water drain hose, and
Having desired space around the appliance for maintenance and ventilation.
Min. 5cm
Min. 5cm | Min. 5cm |
Tube arrangement
L | H | Add. Refrigerant | Provided Tube(M) |
|
| (g/m) |
|
|
|
|
|
15 | 7 | 25 | 4 |
L:Maximum length of the tube connecting the indoor unit and the outdoor unit.
H:The height difference between the indoor unit and the outdoor unit.
Tube length(L)
Indoor unit
Height difference(H) | Outdoor |
| unit |
If the length of the tube is between 7.5m to 15m(maximum length), an additional 25g/m of refrigerant should be added . Additional compressor oil must not be added.
CAUTION: The indoor unit should not be installed below a height of 1.8m.
The outdoor unit should be installed away from the following: Heat source and fan exhausting ;
Director sunlight;
8
The outdoor unit should be installed in an area with, Cool temperature;
Good ventilation;
Desired space for air inlet, outlet and maintenance
| Top obstacle | |
Air inlet | Min. 10cm |
|
| Valve side |
|
| outletAir |
|
| Min. 25cm | Blockage |
Min. 5cm | Air outlet | |
| Min. 40cm |
|
| Ground | Min.10cm |
|
| Air inlet |
Strong base (10x40cm2 concrete or alike). The appliance should be placed not less than 10cm high.
Anchor bolts(4)
Air inlet
Min. 10cm
Concrete or alike
Abo |
|
| 10cm |
ut | 4 | About | |
| 0cm | ||
|
| ||
|
|
|
Fix the base with anchor bolts to reduce vibration and noise.
20