Hisense Group KFR-3208GW Installation of the outdoor unit, Appendix Installation

Models: KFR-3208GW

1 26
Download 26 pages 29.42 Kb
Page 24
Image 24
Install the indoor unit

Appendix: Installation

(3)Any part of the drainpipe should be below the outlet of the indoor unit

 

and the joints should be wrapped with waterproof adhesive tape to

Wire outlet

prevent leakage of condensed water.

Tubes

(4)Bind the tubes, wires and the drainpipe tightly with binding tape, with

 

the drainpipe under the wires.

 

(5)Press down the clamping plate of the tubes and fix the bound wires.

Drainpipe

 

Install the indoor unit

(1)Pull the bound wires out through the wall hole and put the indoor wires together with the indoor unit at the corresponding place of the wall plate. (2)Hook the indoor unit onto the retaining claws on the wall plate and move the unit body slightly to make sure that it is firm.

(3)Hold the two sides of the unit body and press it to the wall plate to ensure secure connection.

4. Installation of the outdoor unit

Mount the outdoor unit

A. Mount the outdoor unit in the selected place.

B. If the outdoor unit is to be mounted on the wall, the wall and the installation bracket should have sufficient intensity to bear the weight of the outdoor unit.

(1)Place the outdoor unit carefully onto the bracket.

(2)Fix the unit onto the bracket with four bottom bolts. The bolts should have anti-vibration pads to prevent falling down of the unit from vibration.

Connect the tubes of the outdoor unit

A. Electric wires

(1)Remove the wire cover of the outdoor unit with a screwdriver. (2)Remove the wire clip.

(3)Connect the wires to the corresponding terminals on the terminal panel.

Caution: All the " Y " -shaped terminals should be plugged into the line bank and the grounding loop terminal should be connected fully.

(4)Tighten all the screws to ensure good connection.

(5)Put the wires into place with a clip and replace the wire cover.

Caution: Never put extra wires into the wire compartment to avoid damage from eddying flow heating.

B. Tubes

The connection of the outdoor tubes is the same as steps (1) and (2) of the indoor unit.

22

Tube clamping plate

Tubes

Drainpipe

Wires

Wall plate

Tubes

Wires

Drainpipe

Tube clamping plate

Wire cover

Page 24
Image 24
Hisense Group KFR-3208GW Installation of the outdoor unit, Appendix Installation, Install the indoor unit