Appendix: Installation
3. Installation of the indoor unit
Remove the wall plate
(1)Remove the fixing screws and keep them for future use (not used during installation).
(2)Press the two triangular signs on the outer shell and remove the fixing clip.
(3)Remove the wall plate.
Mount the wall plate
(1)Determine the correct position of the plate with a level (never use the naked eyes!). The plate should be level.
(2)Fix the plate with §¶6mm expansion bolts for cement walls and with wood screws for wood or plaster walls.
Caution: Adequate space should be reserved for the installation of the indoor unit. To avoid running noise and vibration, the wall plate should be fixed tightly on the wall.
Make the wall hole
Select the position of the hole according to the positions of the indoor and outdoor units. The hole should be slightly lower than the wall plate.
The diameter of the hole is 65mm and the hole should be made with the outside end a little lower.
The site should be cleaned after the hole is made.
Caution: Check carefully before the hole is drilled to make sure that there is no cables or tubes in the area.
Wall plate
Fixing screw
Fixing clip
75 | Right tube |
75 hole center | |
Left tube |
|
hole center |
|
Indoor
Outdoor
Connect the tubes of the indoor unit
A. Connect the electric wires
(1)Open the front panel and remove the cover of the electric box. (2)Remove the wire clip in the electric box.
(3)Put in the wires from the back of the indoor unit and pull them out from the front.
(4)Connect the wires firmly to the terminal panel.
(5)Fix the wires with the clip, replace the cover and close the front panel.
Caution: Make sure that the numbers of the terminals are the same
as those of the terminal panel.
B. Connect the tubes
(1)Do not let dust, dirt, air and water into the tubes during installation, so never remove the tube plugs if installation is not due.
(2)Remove the nuts at the tube joints of the indoor unit, align the center of the tube flare (apply
is applied hereConnecting Flared
tubetube
Caution: Avoid leakage from loose connection or damage of the flare from
Set the outdoor unit
Set the indoor unit