Hitachi 50VS810A, 70VS810 Side Panel Controls, First Time Use, i POWER light, j TEMP indicator

Models: 70VS810 50VS810A

1 84
Download 84 pages 39.24 Kb
Page 8
Image 8
iPOWER light

SIDE PANEL CONTROLS

FIRST TIME USE

iPOWER light

This light is on during normal operation.

Light Blinking Slowly (2 seconds): television lamp is cooling down. It takes 12-15 seconds to warm up and about 2 minutes to cool down.

NOTES:

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

INDICATOR

 

INDICATION

 

MEANING

 

ACTION

 

 

 

 

LIGHT ON

 

NO LAMP LIGHT

 

Need to replace if

 

 

 

 

 

 

or BROKEN LAMP

 

LAMP still does not light by

 

 

LAMP LED

 

 

 

 

 

“Power On” again.

 

 

 

BLINKING

 

WRONG LAMP UNIT

 

 

 

 

 

 

Check assembly condition of

 

 

 

 

 

 

ASSEMBLY / LAMP

 

LAMP UNIT

 

 

 

 

 

 

DOOR OPEN

 

 

 

TEMP

 

LIGHT ON

 

Too hot inside the

 

 

 

 

 

 

 

Call for Service

 

 

 

 

 

 

 

 

 

 

OPTIC unit

 

 

 

LED

 

 

 

 

 

 

 

 

 

BLINKING

 

COOLING FAN STOPPED

 

 

 

 

POWER

 

LIGHT ON

 

NORMAL

 

 

 

 

 

 

OPERATION

 

 

 

 

LED

 

 

 

 

 

 

 

 

 

SHORT BLINKING

 

COOL DOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERMEDIATE BLINKING

 

TV CAN’T RECEIVE ANY REMOTE

 

 

 

 

 

 

 

CONTROL BUTTONS BY

 

 

 

 

 

 

 

 

POWER OFF SEQENCE

 

 

 

 

 

 

LONG BLINKING

 

TV EXECUTING THE

 

 

 

 

 

 

 

 

INITIAL DIGITAL TUNING

 

 

2. If the LAMP, TEMP, and POWER LED are blinking in the order below, the television is warming up.

POWER TEMP jTEMP indicatorLAMP

3.Your Hitachi LCD Rear Projection Television may appear to be OFF when it is set to input 1 ~ input 5 and the video signal is not received from the input jacks. Please make sure the Blue Power light indicator is not lit (OFF) when you are not watching for long lasting performance.

4.Your Hitachi LCD Rear Projection Television has an internal lamp that lights up the TV screen. Make sure to turn off the Power when you do not watch the LCD Rear Projection Television for longer lamp life.

jTEMP indicator

This light is off during normal operation.

If this indicator is lit, the optic unit is too hot. If this indicator is blinking, the cooling fan has stopped. Please call service.

kLAMP indicator - NORMAL OPERATION INDICATOR IS OFF

If light is lit, the lamp has failed. See page 69-72 for lamp replacement procedure. Consult your Hitachi dealer for proper part. If light is blinking, lamp cover is not assembled securely after replacement.

IMPORTANT NOTES:

A small number of missing, discolored, or lit all the time dots or pixels is characteristic of TFT LCD technology due to the manufacturing process irrespective of manufacturer.