■Automatic power OFF

Automatic power OFF

電源自動關閉功能

The power will be cut automatically at the end of operation.

運轉結束後,電源開關將自動切斷。

The power will be automatically cut if the washing machine keeps one of the following status for above 1 hour.

在下列情況中,若將洗衣機放置1小時以上,則電源開關將自動切斷。
1)Pause
暫停狀態
2)Lid open
機蓋開￿的狀態
3)Abnormality alarm describer in page 46
如同46頁的異常警報狀態

With no pressing on "START/PAUSE" button in 5 minutes after the power on, the power will be cut automatically.

接通電源後,若不按下￿動按鈕,則5分鐘之後電源開關將自動切斷。

The following cases are not the failures

以下現象並非故障

Case 現象

 

Cause 原因

 

Supply water during the course

 

of washing.

 

洗衣過程中供水。

 

 

 

The water can no be charged

 

when starting washing form rinse.

 

從沖洗開始洗衣時,無法供水。

 

 

About

After connecting the water supply

the water

pipe, water will come in from the

charging

water supply opening if turning

on the tap.

關於供水

供水管連接後,打開水龍頭,有水

 

從供水口處流出。

 

 

 

The pulsator stop rotating during

 

the charging for about 1 minutes.

 

供水過程中攪拌翼停止旋轉,供水

 

停止約1分鐘。

 

 

 

The rotary water supply takes a

 

longer time.

 

旋轉供水時間變長

 

 

 

"Rustle" happens as rotating the

 

washing basket by hand.

About

用手轉動洗衣槽,發出沙沙

音。

the

 

It sounds "Karcha" at the beginning

sound

of washing or spinning.

關於聲音

洗衣或脫水開始時發出卡嚓

 

音。

 

 

 

It buzzes during the operation.

 

運轉過程中發出–”

 

聲音。

 

 

Supply water automatically if the water level drops during the course of washing.

洗衣過程中若水位下降,便會自動補水。

The rinse water can only be charged after drainage and spinning.

排水和脫水之後才開始進沖洗用水。

With the application of decompression valve, the close of valve needs certain duration.

由於採用了減壓閥,閥門關閉需要一定的時間。

It may be influenced by outside interference, and it takes some time for the sensor to detect the interference.

可能受到了外來乾擾的影響,而傳感器檢測乾擾需要一定時間。

As the water level of washing machine is too low.

這是由於洗衣机的供水量太小所引起的。

The sound comes from the water flow in the liquid balance used to relieve the spinning vibration.

這是降低脫水振動的液體平衡器中水流的聲音。

That is generated during the mode switch of the clutch. (the strength of the sound varies with the sound duration.)

這是離合器進行模式切換時的聲音。 (聲音大小隨發生時間而變化。)

That is the electromagnetic sound of the motor switched on and off.

這是電機通斷電或電閘的電磁音。