Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification
42
October 29, 2008 2:44 pm
12.4 Non-operating shock
The drive will not sustain permanent damage or loss of recorded data after being subjected to the environments as described
below.

12.4.1 Half sinewave shock pulse

80 G, 11 ms duration, half sinewave pulse
250 G, 2 ms duration, half sinewave pulse
The shocks are applied in each direction of the drive for the three mutually perpendicular axes, one axis at a time. The input
level is applied to a base plate where the drive is attached using four mounting screws.

12.4.2 Rotational shock

30,000 radians /second2, 1 ms duration
20,000 radians /second2, 2 ms duration
The shock input is applied around the axis of the actuator pivot. The shock input does not displace the heads from the actuator
latched position.