Inverter Keypad Operation

Run Key Enable LED

Parameter Display

Run/Stop LED

Program/Monitor LED

Power LED

 

 

HITACHI

POWER

 

 

 

PRGRUN

5 0.0

HzA

 

 

STOP

 

RUN

 

RESET

 

 

 

MIN

MAX

FUNC. 1 2 STR

Display Units LEDs

Hertz

Amperes

Potentiometer

Enable LED

Potentiometer

Stop/Reset Key

Run Key

Up/Down Keys

Store Key

Function Key

Run/Stop LED – ON when the inverter output is ON and the motor is developing torque, and OFF when the inverter output is OFF (Stop Mode).

Program/Monitor LED – ON when the inverter is ready for parameter editing (Program Mode). It is OFF when the parameter display is monitoring data (Monitor Mode).

Run Key Enable LED – ON when the inverter is ready to respond to the Run key, OFF when the Run key is disabled.

Run Key – Press this key to run the motor (the Run Enable LED must be ON first). Parameter F_04, Keypad Run Key Routing, determines whether the Run key generates a Run FWD or Run REV command.

Stop/Reset Key – Press this key to stop the motor when it is running (uses the programmed deceleration rate). This key will also reset an alarm which has tripped.

(continued, next page...)

5

Page 6
Image 6
Hitachi NB5741XD manual Inverter Keypad Operation, Hitachi