Default

 

Func.

Name / Description

Value

Set

Code

–FE / –FU /

Value

 

 

 

 

 

 

 

–FR

 

 

 

 

 

 

 

 

 

 

 

C_21

Terminal [11] function

Six option

01

 

 

 

 

codes available

 

 

C_22

Terminal [12] function

00

 

(see page 22)

 

 

 

 

 

 

 

 

 

 

 

 

C_23

[FM] signal selection

 

Three option

00

 

 

 

 

codes available

 

 

 

 

 

(see page 22)

 

 

 

 

 

 

 

 

C_31

Terminal [11] active

 

• 00 Normally

— / 00 / —

 

 

state (–FU)

 

open (NO)

 

 

 

 

 

• 01 Normally

 

 

 

Reserved (–FE / –FR)

 

00 / — / 00

 

 

 

closed (NC)

 

 

 

 

 

 

 

 

 

 

 

 

C_32

Terminal [12] active

 

 

— / 00 / —

 

 

state (–FU)

 

 

 

 

 

 

 

 

 

 

 

Terminal [11] active

 

 

00 / — / 00

 

 

state (–FE / –FR)

 

 

 

 

 

 

 

 

 

 

C_33

Alarm relay terminal

 

 

01

 

 

active state

 

 

 

 

 

 

 

 

 

 

C_41

Overload level setting

 

 

Rated

 

 

 

 

 

current of

 

 

 

 

 

each inverter

 

 

 

 

 

C_42

Frequency arrival setting for accel

0.0

 

 

 

 

 

C_43

Arrival frequency setting for decel

0.0

 

 

 

 

 

C_44

PID deviation level setting

3.0

 

 

 

 

 

 

 

C_91

Debug mode enable

 

 

00

 

 

• 00 Display

• 01 No display

 

 

 

 

 

 

 

 

20

Page 21
Image 21
Hitachi NB5741XD manual Rated Current