Error

Name

Probable Cause(s)

Code

 

 

 

 

 

 

 

 

E35

Thermistor

• Thermistor input, [THM] and [L], is

 

 

over the temp. threshold

---

Under-voltage (brown-

• Low input voltage caused the

out) with output shutoff

inverter to turn OFF the motor output

 

 

and try to restart. If unsuccessful, a

 

 

trip occurs.

 

 

 

Error Trip Conditions

Use function code D_08 to access the error trip conditions for the current error as shown in the table below. Use the Up and Down arrow keys to scroll through the trip condition parameters.

 

Step

Display

 

 

 

 

 

 

 

 

1.

Access D_08

d 08

 

 

 

 

 

2.

Press Function Key

If no error:

 

 

 

_ _ _

 

 

 

 

 

 

 

If error exists:

 

 

 

Exx

 

 

 

(error code)

 

 

 

 

3.

Press Up/Dn key (if

Output frequency at

error exists)

trip point:

 

 

 

10.0

 

 

 

 

 

 

Motor current at trip

 

 

 

1point:

0.025

2

DC bus voltage at trip

point:

 

 

189.8

 

 

 

 

 

10

Page 11
Image 11
Hitachi NB5741XD manual Error Trip Conditions, Step Display