“A” Group: Standard Functions

 

 

Default

 

Func.

Name / Description

Value

Set

Code

–FE / –FU /

Value

 

 

 

–FR

 

 

 

 

 

 

 

 

 

A_01

Frequency source setting

01 / 01 / 00

 

 

• 00 Keypad potentiometer

 

 

 

• 01 Control terminal

 

 

 

• 02 Function F_01 setting

 

 

 

 

 

 

A_02

Run command source setting

01 / 01 / 02

 

 

• 01 Input terminal FW or RV (assign-

 

 

 

able)

 

 

 

• 02 Run key on keypad, or digital

 

 

 

operator

 

 

 

 

 

 

A_03

Base frequency setting

50.0 / 60.0 /

 

 

 

60.0

 

 

 

 

 

A_04

Maximum frequency setting

50.0 / 60.0 /

 

 

 

60.0

 

 

 

 

 

A_11

O/OI–L input active range start

0.0

 

 

frequency

 

 

 

 

 

 

A_12

O/OI–L input active range end frequency

0.0

 

 

 

 

 

A_13

O/OI–L input active range start voltage

0

 

 

 

 

 

A_14

O/OI–L input active range end voltage

100

 

 

 

 

 

A_15

O/OI–L input start frequency enable

01

 

 

• 00 Use A_11 starting value)

 

 

 

• 01 Use 0 Hz

 

 

 

 

 

 

A_16

External frequency filter time constant

8

 

 

 

 

 

A_20

Multi-speed frequency setting

0

 

 

 

 

 

A_21

Multi-speed frequency settings

0 / 0 / 5

 

A_22

 

0 / 0 / 10

 

A_23

 

0 / 0 / 15

 

A_24

 

0 / 0 / 20

 

A_25

 

0 / 0 / 30

 

A_26

 

0 / 0 / 40

 

A_27

 

0 / 0 / 50

 

A_28

 

0 / 0 / 60

 

A_29..

 

0 / 0 / 0

 

..A_35

 

 

 

 

 

 

 

A_38

Jog frequency setting

1.0

 

 

 

 

 

A_39

Jog stop mode

00

 

 

• 00 Free-run stop, jogging disabled

 

 

 

during motor run

 

 

 

• 01 Controlled deceleration, jogging

 

 

 

disabled during motor run

 

 

 

• 02 DC braking to stop, jogging

 

 

 

disabled during motor run

 

 

 

 

 

 

15