Hitachi PJ-TX100 Related messages continued, The internal portion temperature is rising

Models: PJ-TX100

1 50
Download 50 pages 52.66 Kb
Page 36
Image 36
Related messages (continued)

Troubleshooting

Related messages (continued)

Message

Description

 

The horizontal or vertical wavelength of the inputted

SYNC IS OUT OF RANGE

signal is outside of the response parameters of this unit.

ON *** fH *****kHz fV *****Hz

Please confi rm the specs for this unit or the signal source

 

 

specs.

 

The internal portion temperature is rising.

 

Please turn the power OFF, and allow the unit to cool down

 

at least 20 minutes. After having confi rmed the following

CHECK THE AIR FLOW

items, please turn the power ON again.

 

• Is there blockage of the air passage aperture?

 

• Is the air fi lter dirty?

 

• Does the peripheral temperature exceed 35°C?

CLEAN THE AIR FILTER

A note of precaution when cleaning the air filter.

Please immediately turn the power OFF, and clean or

POWER OFF FIRST,

change the air fi lter by referring to the “Air Filter” section of

THEN CLEAN THE AIR

this manual. After you have cleaned or changed the air fi lter,

FILTER.

please be sure to reset the fi lter timer. If the same message

AFTER CLEANING THE AIR

is displayed after the treatment, please clean the transparent

FILTER,

area of fi lter cover and the dust-detecting window, according

RESET THE FILTER TIMER.

to the following.

The internal portion temperature is rising.CAUTION ►The transparent area of filter cover and the dust-detecting window should be cleaned for normal operation of the optical dust detecting system. Please pay attention not to remain fiber or fragment of cloth inside the duct.

1. Turn off the projector, and unplug the power cord.

2. After making sure that the projector has cooled adequately, remove the fi lter cover.

Hold the release buttons of the fi lter cover, while pulling up it.

3. Wipe the transparent area of the fi lter cover by using a swab or a soft cloth.

4. Remove the air fi lter.

Hold the release buttons of the air fi lter, while pulling up it.

5. Wipecloth. the dust-detecting window by using a soft

6. Replace the air fi lter and fi lter cover.

Release buttons

Filter cover

Transparent A note of precaution when cleaning the air filter.Manual backgroundManual backgroundManual backgroundManual backgroundManual background area Manual backgroundManual backgroundManual backgroundManual background

Air fi lter

Manual background Release buttons

Dust detecting window

(Rear side)

(Bottom side)

36

Page 36
Image 36
Hitachi PJ-TX100 user manual Related messages continued, The internal portion temperature is rising