Troubleshooting

Regarding the indicator lamps

Lighting and fl ashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please respond

in accordance with the instructions within the table. If the same indication is displayed after the treatment, or if an indication other than the following is displayed, please contact your dealer or service company.

NOTE • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “￿” (OFF) side of the main power switch, and wait at least 45 minutes. After the projector has suffi ciently cooled down, please make confi rmation of the attachment state of the lamp and lamp cover, and then turn the power on again.

ENGLISH

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

Lighting

Turned

Turned

The projector is in a standby state.

In Orange

off

off

Please refer to the section “Power On/Off”.

 

 

 

 

Blinking

Turned

Turned

The projector is warming up.

In Green

off

off

Please wait.

Lighting

Turned

Turned

The projector is in an on state.

In Green

off

off

Ordinary operations may be performed.

 

 

 

 

Blinking

Turned

Turned

The projector is cooling down.

In Orange

off

off

Please wait.

 

 

 

The projector is cooling down. A certain error

Blinking

(discre-

(discre-

has been detected.

In Red

tionary)

tionary)

Please wait until the POWER indicator fi nishes blink,

and then perform the proper response measure using

 

 

 

the item descriptions below as reference.

 

 

 

 

 

 

 

The lamp does not light, and there is a

 

 

 

possibility that interior portion has become

 

 

 

heated.

Blinking

 

 

Please turn the power off, and allow the unit to cool

 

 

down at least 20 minutes. After the projector has

In Red

Lighting

Turned

suffi ciently cooled down, please make confi rmation of

or

In Red

off

the following items, and then turn the power on again.

Lighting

• Is there blockage of the air passage aperture?

 

 

In Red

 

 

• Is the air fi lter dirty?

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

If the same indication is displayed after the treatment,

 

 

 

please change the lamp by referring to the section

 

 

 

“Lamp”.

 

 

 

 

37

Page 37
Image 37
Hitachi PJ-TX100 user manual Regarding the indicator lamps