Lamp replacement

If the indicators or a message prompts you to replace the lamp, replace the lamp as soon as possible.

1. Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least 45 minutes.

2. Contact your dealer to prepare a new lamp. Tell the dealer your lamp type number: DT00661. If the projector is mounted on the ceiling, or if the lamp

has broken, also ask the dealer to replace the lamp.

ENGLISH

In the case of replacement by yourself,

3. After making sure that the projector has cooled adequately, slowly fl ip over the projector, so that the bottom is facing up.

4. Unscrew the screw (marked by arrow) of the lamp cover, the slide and take the lamp cover

up.

5. Unscrew the 2 screws (marked by arrow), and slowly pick up the lamp by the handles.

6. Insert the new lamp, and retighten firmly two screws unscrewed in the previous process to

lock it in place.

7. Slide the lamp cover into place, and retighten firmly the screw of the lamp cover unscrewed

in the process no. 4.

8. Turn on the projector power, and reset the lamp timer.

(1)While the projector running, press the MENU button to open the menu.

Bottom side

Lamp cover

Screw of the lamp cover

Screw

Screw

Handles

(2)Choose the "OPTION" on the menu using the ▲/▼ button, then press the ► button or ENTER button.

(3)Choose the "LAMP TIME" using the ▲/▼ button, then press and hold the RESET button for 3 seconds.

(4)Choose the "RESET" using the ▲ button.

NOTE • When the lamp has been replaced after the message of "THE POWER WILL TURN OFF AFTER 0hr." is displayed, complete the following operation within 10 minutes of switching power on.

Incorrectly resetting of the lamp timer (resetting without replacement, or neglect of resetting after replacement) will result in incorrect message functions.