Phenomena that may easily be mistaken for machine defects (continued)

Troubleshooting

Phenomena that may easily be mistaken for machine defects (continued)

Phenomenon

Cases not involving a machine defect

Reference

page

 

 

 

The PC cannot detect the projector as a plug and

 

 

play monitor.

8

 

Make sure that the PC’s can detect a plug and play monitor

 

 

 

using other plug and play monitor.

 

 

 

 

 

If the connected PC has a DVI output, the driver

 

 

software of the DVI board is too old.

-

No pictures are

Consult with the dealer of your PC to install new software.

 

displayed.

The signal source cannot output both a DVI signal

 

 

 

 

and a VGA signal simultaneously.

-

 

Disconnect the VGA connection when you use the DVI

 

 

 

input.

 

 

 

 

 

If the output signal can be selected on the PC, it isn't

 

 

selected properly

-

 

Select the digital output for DVI connection.

 

 

 

 

Colors have a

Color settings are not correctly adjusted.

 

Perform picture adjustments by changing the COLOR TEMP,

18, 19

faded- out

COLOR and/or TINT settings, using the menu functions.

 

appearance, or

 

 

 

COLOR SPACE setting is not suitable.

 

Color tone is

24

poor.

Change the COLOR SPACE setting to AUTO, RGB,

SMPTE240, REC709 or REC601.

 

 

 

 

 

 

 

The brightness and/or contrast are adjusted to an

 

 

extremely low level.

16, 18,

 

Adjust the BRIGHT and/or CONTRAST settings to a higher

19

 

level using the menu function.

 

 

 

 

 

The IRIS setting lowers the brightness.

26

Pictures appear

Set the IRIS to +10.

 

dark.

The WHISPER function is working.

 

 

 

 

Select the NORMAL to the item WHISPER in the SETUP

26

 

menu.

 

 

 

 

 

The lamp is approaching the end of its product

 

 

lifetime.

32

 

Replace the lamp.

 

 

 

 

 

Either the focus and/or horizontal phase settings are

 

 

not properly.

14, 22

 

Adjust the focus using the focus knob, and/or H PHASE

Pictures appear

 

using the menu function.

 

blurry.

 

 

The lens is dirty or misty.

 

 

 

 

Clean the lens by referring to the section “Caring For The

34

 

Lens”.

 

 

 

 