11. Troubleshooting guide

Case 1. Starting failure

 

 

 

CHECK

PROBABLE CAUSES

ACTION

 

fuel tank

Α incorrect fuel

Α drain it and use correct fuel

 

fuel filter

Α fuel filter is clogged

Α clean

 

carburetor adjustment screw

Α out of normal range

Α adjust to normal range

 

sparking (no spark)

Α spark plug is fouled/wet

Α clean/dry

 

 

Α plug gap is incorrect

Α correct (GAP: 0.6 ~ 0.7 mm)

 

spark plug

Α disconnected

Α retighten

Case 2. Engine starts but does not keep running/hard re-starting

 

 

CHECK

PROBABLE CAUSES

ACTION

 

fuel tank

Α incorrect fuel or staled fuel

Α drain it and use correct fuel

 

carburetor adjustment screw

Α out of normal range

Α adjust to normal range

 

muffler, cylinder (exhaust port)

Α carbon is built-up

Α wipe away

 

air cleaner

Α clogged with dust

Α wash

 

cylinder fin, fan cover

Α clogged with dust

Α clean

When your unit seems to need further service, please consult with our HITACHI service shop in your area.