CHAPTER5 OPERATING
5.5 Profidrive specific parameters
The table below shows which Profidrive specific parameters that are supported by the
Table 5-1 Profidrive parameters
PNU - |
|
|
|
|
|
Parameter Number | Description |
|
| Range |
|
915 | Refer to chapter 5.3.3 and 5.4.3 for how to assign PZD | Parameter range: | R/W | ||
words. Use the parameter | 1 – 418. |
| |||
Assignment of PZD write word | chapter 5. |
|
|
| |
Please note: Parameters will be lost when turning | 1 – 8. |
| |||
| power off unless parameter 971 has been written with |
|
| ||
|
|
|
|
| |
916 | Refer to chapter 5.3.3 and 5.4.2 for how to assign PZD | Parameter range: | R/W | ||
words. Use the parameter | 1 – 418. |
| |||
Assignment of PZD read word | chapter 5. |
|
|
| |
Please note: Parameters will be lost when turning | 1 – 8. |
| |||
| power off unless parameter 971 has been written with |
|
| ||
|
|
|
|
| |
918 | Returns address switch setting. |
| R | ||
|
|
|
|
| |
|
|
|
|
| |
927 | 1 – PKW interface enabled. Parameters can be | 0, 1 | R/W | ||
read/written. |
|
|
|
| |
Parameter edit rights | 0 – PKW interface disabled, only parameter 927 can |
|
| ||
| be read/written. |
|
|
|
|
928 | 1 – Option board will send control word, reference and | 0, 1 | R/W | ||
will update |
|
|
| ||
Control rights (process data). | 0 – PZD not enabled. |
|
|
| |
947 | Fault. Codes as described in table | - | R | ||
|
| ||||
Indexed Fault memory |
|
| |||
|
|
| |||
|
|
| |||
|
|
| |||
|
|
| |||
|
|
| |||
963 | the baudrate of the | R | |||
0: 12 Mbit/s 1: 6 Mbit/s 2: 3 Mbit/s 3: 1.5 Mbit/s |
|
| |||
4: 500 kbit/s | 5: 187.5 kbit/s | 6: 93.75 kbit/s |
|
| |
| 7: 45.45 kbit/s | 8: 19.2 kbit/s | 9: 9.6 kbit/s |
|
|
964 | Bit 15 represents the type of inverter, 0 – SJxxx, 1 – | 012Ch, 812Ch | R | ||
LxxxP. Rest of the word represents the model number. |
|
| |||
Device identification | SJ300 - 0x012C |
|
|
| |
| L300P - 0x812C |
|
|
| |
965 | Returns the Profidrive profile version used in the | 2 | R | ||
implementation |
|
|
|
| |
Profile version |
|
|
|
|
|
967 | Shows the latest received control word in hex format | Bit | R | ||
Refer to chapter 5.3.1 for detailed information about |
|
| |||
Control Word | the control word. |
|
|
| |
968 | Shows the latest status word in hex format | Bit | R | ||
Refer to chapter 5.3.1 for detailed information about |
|
| |||
Status Word | the status word. |
|
|
| |
971 | Please note that it will take approximately 10s for this | 0, 1 | W | ||
process to finish (inverter must be stopped). |
|
| |||
Transfer into | 0 – No function. |
|
|
| |
memory | 1 – Will save inverter parameters to |
|
| ||
| memory and the Profile specific parameters to FLASH. |
|
|
19