CHAPTER5 OPERATING

5.5 Profidrive specific parameters

The table below shows which Profidrive specific parameters that are supported by the SJ-PB(T).

Table 5-1 Profidrive parameters

PNU -

 

 

 

 

 

Parameter Number

Description

 

 

Range

 

915

Refer to chapter 5.3.3 and 5.4.3 for how to assign PZD

Parameter range:

R/W

words. Use the parameter cross-reference list in

1 – 418.

 

Assignment of PZD write word

chapter 5.

 

 

Sub-index range:

 

3-10

Please note: Parameters will be lost when turning

1 – 8.

 

 

power off unless parameter 971 has been written with

 

 

 

“0->1”.

 

 

 

 

916

Refer to chapter 5.3.3 and 5.4.2 for how to assign PZD

Parameter range:

R/W

words. Use the parameter cross-reference list in

1 – 418.

 

Assignment of PZD read word

chapter 5.

 

 

Sub-index range:

 

3-10

Please note: Parameters will be lost when turning

1 – 8.

 

 

power off unless parameter 971 has been written with

 

 

 

“0->1”.

 

 

 

 

918

Returns address switch setting.

 

1-99

R

 

 

 

 

 

Profibus-DP slave address

 

 

 

 

 

927

1 – PKW interface enabled. Parameters can be

0, 1

R/W

read/written.

 

 

 

 

Parameter edit rights

0 – PKW interface disabled, only parameter 927 can

 

 

 

be read/written.

 

 

 

 

928

1 – Option board will send control word, reference and

0, 1

R/W

will update PZD3-10.

 

 

 

Control rights (process data).

0 – PZD not enabled.

 

 

 

947

Fault. Codes as described in table 5-2 below.

-

R

Sub-index 1 = Not acknowledged fault.

 

 

Indexed Fault memory

Sub-index 9 = Latest acknowledged fault.

 

 

 

Sub-index 17 = 2nd latest acknowledged fault.

 

 

 

Sub-index 25 = 3rd latest acknowledged fault.

 

 

 

Sub-index 33 = 4th latest acknowledged fault.

 

 

 

Sub-index 41 = 5th latest acknowledged fault.

 

 

 

Sub-index 49 = 6th latest acknowledged fault.

 

 

963

the baudrate of the Profibus-DP network

0-9

R

0: 12 Mbit/s 1: 6 Mbit/s 2: 3 Mbit/s 3: 1.5 Mbit/s

 

 

PROFIBUS-DP baud rate

4: 500 kbit/s

5: 187.5 kbit/s

6: 93.75 kbit/s

 

 

 

7: 45.45 kbit/s

8: 19.2 kbit/s

9: 9.6 kbit/s

 

 

964

Bit 15 represents the type of inverter, 0 – SJxxx, 1 –

012Ch, 812Ch

R

LxxxP. Rest of the word represents the model number.

 

 

Device identification

SJ300 - 0x012C

 

 

 

 

L300P - 0x812C

 

 

 

965

Returns the Profidrive profile version used in the SJ-PB

2

R

implementation

 

 

 

 

Profile version

 

 

 

 

 

967

Shows the latest received control word in hex format

Bit 0-15

R

Refer to chapter 5.3.1 for detailed information about

 

 

Control Word

the control word.

 

 

 

968

Shows the latest status word in hex format

Bit 0-15

R

Refer to chapter 5.3.1 for detailed information about

 

 

Status Word

the status word.

 

 

 

971

Please note that it will take approximately 10s for this

0, 1

W

process to finish (inverter must be stopped).

 

 

Transfer into non-volatile

0 – No function.

 

 

 

memory

1 – Will save inverter parameters to non-volatile

 

 

 

memory and the Profile specific parameters to FLASH.

 

 

19

Page 23
Image 23
Hitachi SJ-PB(T) instruction manual Profidrive specific parameters, Profidrive parameters