CHAPTER6 COUNTERMEASURE FOR ABNORMALITY

6.1 Trip display

When the inverter is in a tripped state, the inverter displays an error code (See table below). The trip history monitor (d081 to d086) also displays the same error code as the inverter.

Trip

6.2 Protection function list

The table below describes an error code for protecting the inverter and the motor.

No.

Function

Error

Action

 

 

Display

 

1

Network option’s

E70

This error is displayed, disconnection occurs when timeout is

 

communication error

 

occurred, while the inverter is operating with CANopen. (Trip

 

 

 

is caused by P045 setting)

2

External trip

E12

This error is displayed, when Halt is set to 1 toward control

 

 

 

word(Index:6040h) in BIT8(Halt).

With regard to the other errors except table above, refer to Inverter instruction manual chapter 4 Explanation of function.

6.3 Countermeasure for a trip state

The table below only corresponds to additional trip codes, with regard to the other countermeasures refer to Inverter instruction manual chapter 4 Explanation of function.

Trip code

Name of trip

Cause

Conformation

Countermeasure

E70

CANopen

Baud

 

rate

is

Check Baud

Install correct Baud rate and

 

Communication

different.

 

 

rate

then reset the power supply.

 

error

Wiring distance does

Check the wiring

Adjust the setting to the

 

 

 

 

not match with Baud

distance

matching Baud rate.

 

 

rate

 

 

 

 

Adjust Wiring distance.

 

 

Defective

connector

Check the area of

Improve the connection and

 

 

for

signal

cable

connection.

then reset the power supply.

 

 

causes

connection

 

 

 

 

fail.

 

 

 

 

 

 

 

Terminating resistor

Check the

Connect the terminating

 

 

is not connected.

Connection

Resistor and then reset the

 

 

 

 

 

 

 

power supply

 

 

 

 

 

 

 

E12

External

Control

 

 

Check as mentioned

Set Halt to 0 toward Control

 

Trip

word(Index:6040h)

left.

word(Index:6040h)Bit8(Halt).

 

 

Bit8:Halt

 

 

 

 

 

 

 

 

 

 

 

 

21

Page 25
Image 25