English

ADJUSTING AIR PRESSURE

WARNING

Staple Magazine

￿Do not exceed 120 psi (8.3 bar 8.5 kgf/ cm2).

Adjust the air pressure at recommended operating pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm2) according to the length of staples and the hardness of workpiece.

The correct air pressure is the lowest pressure which will do the job. Using the Stapler at a higher than required air pressure unnecessarily over stresses the Stapler.

LOADING STAPLES

WARNING

(3)Pull the staple feeder backward. Then, detach it from the groove of magazine and softly bring the staple back as if it were being gently pushed, avoiding any impact.

￿When loading staples into Stapler,

1)do not pull trigger;

2)do not depress push lever; and

3)keep Stapler pointed downward.

(1)Pull the staple feeder backward and attach it securely to a groove of the magazine.

Groove

Staple feeder

The Stapler is now ready to operate.

CAUTION

If the staple feeder is released all of a sudden, it can return abruptly, causing deformation and/or scatter, eventually ending up in clogged staples.

Be absolutely sure to bring back the staple feeder, avoiding any impact.

STAPLER OPERATION

Read section titled “SAFETY”(pages 5 – 8).

Staple feeder

(2)Place the staple strip over the magazine. Make sure that the staple strip slides freely on the magazine.

14 —

DANGER

￿ Operators and others in work area MUST wear safety glasses with side shields which conforms to ANSI Z87.1 specifications.