(1)DISCONNECT AIR HOSE FROM STAPLER.

REMOVE ALL STAPLES FROM STAPLER.

￿ALL SCREWS MUST BE TIGHTENED. If any screws are loose, tighten them.

￿THE PUSH LEVER AND TRIGGER MUST MOVE SMOOTHLY.

Trigger

Push lever

Do not connect air hose

(2)Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm2).

Connect the air hose.

Do not load any staples in the Stapler.

￿THE STAPLER MUST NOT LEAK AIR.

Hold the Stapler downward and pull the trigger.

English

￿THE STAPLER MUST NOT OPERATE. Pull trigger

Push lever

(3)With finger off the trigger, depress the push lever against the workpiece.

￿THE STAPLER MUST NOT OPERATE. Do not pull trigger

Depress push lever

(4)Without touching the trigger, depress the push lever against the workpiece.

Pull the trigger.

￿THE STAPLER MUST OPERATE.

(5)With the Stapler off the workpiece, pull the trigger.

Depress the push lever against the workpiece.

￿THE STAPLER MUST OPERATE.

(6)If no abnormal operation is observed, you may load staples in the Stapler.

Drive staples into the workpiece that is the same type to be used in the actual application.

￿THE STAPLER MUST OPERATE PROPERLY.

— 13 —