Hobart AM14C ML-110977, AM14 ML-110976 manual Electrical Data, Vent Fan Control

Models: AM14C ML-110977 AM14 ML-110976

1 20
Download 20 pages 26.01 Kb
Page 11
Image 11
ELECTRICAL DATA

 

 

ELECTRICAL DATA

 

 

 

 

 

 

 

 

 

 

Minimum Circuit Ampacity

 

 

 

Maximum Protective Device

Model

Volts / Hz / Ph

Tank Heat

 

AMPS

 

 

 

 

 

 

Dishwasher ONLY

 

Optional 13 KW

 

 

 

 

Electric Booster ONLY

 

 

 

 

 

 

 

 

 

 

 

 

208 - 240 / 60 / 1

Electric

50

 

 

 

 

 

 

 

 

Gas

15

 

 

 

 

 

 

 

 

 

 

 

 

 

208 / 60 / 1

Electric

 

 

80

 

 

 

 

 

 

 

240 / 60 / 1

Electric

 

 

80

AM14

 

 

 

 

 

208 - 240 / 60 / 3

Electric

30

 

 

 

 

 

 

 

AM14C

Gas

15

 

 

 

 

 

 

208 / 60 / 3

Electric

 

 

50

 

 

 

 

 

 

 

240 / 60 / 3

Electric

 

 

50

 

 

 

 

 

 

 

480 / 60 / 3

Electric

15

 

25

 

 

 

 

 

 

Gas

15

 

 

 

 

 

 

 

 

 

 

 

 

Compiled in accordance with the national electrical code, ANSI / NFPA 70 (latest edition).

OPTIONAL EQUIPMENT CONNECTIONS — Vent Fan and Gas Booster

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.

Vent Fan Control

The vent fan control feature is standard on machines with gas heat; it is a field installable accessory on machines with electric heat.

The maximum switching rating for a vent fan control relay connected to terminals VFC1 and VFC2 is

1.5Amps. The vent fan control relay provides switch contacts only and does not provide power to the vent fan motor. When the dishwasher is connected to the vent fan, the vent fan is switched on when the dishwasher is on, and off when the dishwasher is off.

Hobart Infrared Booster Gas Water Heater

The maximum rating for connecting a Hobart Model IB57 Dishwasher Activated infrared gas booster water heater to BSTR1 and BSTR2 is 0.5 Amp at 24 Volts. If a Stand Alone Booster Heater is used, no electrical connection to the dishwasher is allowed. Refer to the Infrared Booster Gas Water Heater Manual for additional installation details.

– 11 –

Page 11
Image 11
Hobart AM14C ML-110977, AM14 ML-110976 manual Electrical Data, Vent Fan Control, Hobart Infrared Booster Gas Water Heater