| ELECTRICAL DATA |
|
| |
|
|
|
|
| |
|
|
| Minimum Circuit Ampacity | ||
|
|
| Maximum Protective Device | ||
Model | Volts / Hz / Ph | Tank Heat |
| AMPS | |
|
|
| |||
|
|
| Dishwasher ONLY |
| Optional 13 KW |
|
|
|
| Electric Booster ONLY | |
|
|
|
|
| |
|
|
|
|
|
|
| 208 - 240 / 60 / 1 | Electric | 50 |
|
|
|
|
|
|
| |
| Gas | 15 |
|
| |
|
|
|
| ||
|
|
|
|
|
|
| 208 / 60 / 1 | Electric |
|
| 80 |
|
|
|
|
|
|
| 240 / 60 / 1 | Electric |
|
| 80 |
AM14 |
|
|
|
|
|
208 - 240 / 60 / 3 | Electric | 30 |
|
| |
|
|
|
|
| |
AM14C | Gas | 15 |
|
| |
|
|
| |||
| 208 / 60 / 3 | Electric |
|
| 50 |
|
|
|
|
|
|
| 240 / 60 / 3 | Electric |
|
| 50 |
|
|
|
|
|
|
| 480 / 60 / 3 | Electric | 15 |
| 25 |
|
|
|
|
| |
| Gas | 15 |
|
| |
|
|
|
| ||
|
|
|
|
|
|
Compiled in accordance with the national electrical code, ANSI / NFPA 70 (latest edition).
OPTIONAL EQUIPMENT CONNECTIONS — Vent Fan and Gas Booster
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Vent Fan Control
The vent fan control feature is standard on machines with gas heat; it is a field installable accessory on machines with electric heat.
The maximum switching rating for a vent fan control relay connected to terminals VFC1 and VFC2 is
1.5Amps. The vent fan control relay provides switch contacts only and does not provide power to the vent fan motor. When the dishwasher is connected to the vent fan, the vent fan is switched on when the dishwasher is on, and off when the dishwasher is off.
Hobart Infrared Booster Gas Water Heater
The maximum rating for connecting a Hobart Model IB57 Dishwasher Activated infrared gas booster water heater to BSTR1 and BSTR2 is 0.5 Amp at 24 Volts. If a Stand Alone Booster Heater is used, no electrical connection to the dishwasher is allowed. Refer to the Infrared Booster Gas Water Heater Manual for additional installation details.
– 11 –