Diagnostic Error Codes

 

 

 

 

 

 

 

Test Error Codes

 

 

 

 

 

 

Error Code

Description

 

Recommended Action

 

 

 

 

 

 

 

XXXX-02

Drive not installed.

Check cable connections.

 

 

 

 

 

 

 

 

 

XXXX-03

Media not in drive.

Check for and install data CD or write-enabled

 

 

 

 

tape in drive.

 

 

 

 

 

 

 

 

XXXX-05

Seek failure.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-06

Drive timed out.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-07

Drive busy.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-08

Drive already reserved.

Replace the indicated device.

 

 

 

 

 

 

 

 

 

XXXX-09

Unknown.

 

 

 

 

 

 

 

 

 

 

 

 

XXXX-10

Unknown.

 

 

 

 

 

 

 

 

 

 

 

XXXX-11

Media soft error.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-12

Drive not ready.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-13

Media error.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-14

Drive hardware error.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-15

Illegal drive command.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-16

Media was changed.

Replace the indicated device.

 

 

 

 

 

 

 

 

 

XXXX-17

Tape write-protected.

1.

Disable write-protect on tape cartridge.

 

 

 

 

2.

Replace tape drive.

 

 

 

 

 

 

 

 

XXXX-18

No data detected.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-21

Drive command aborted.

Replace the indicated device.

 

 

 

 

 

 

 

 

 

65XX-24

Media hard error.

1.

Back up data and perform Surface Analysis

 

 

 

 

 

to reallocate defect.

 

 

 

 

2.

Replace drive.

 

 

 

 

 

 

 

 

 

66XX-24

Media hard error.

1.

Replace current data CD with different data

 

 

 

 

 

CD.

 

 

 

 

2.

Replace drive.

 

 

 

 

 

 

 

 

 

67XX-24

Media hard error.

1.

Ensure correct media type for this tape

 

 

 

 

 

drive.

 

 

 

 

2.

Replace current tape with new tape.

 

 

 

 

3.

Replace tape drive.

 

 

 

 

 

 

 

 

 

XXXX-25

Unknown.

 

 

 

 

 

 

 

 

 

 

 

XXXX-30

Controller timed out.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-31

Unrecoverable error.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-32

Controller/drive disconnected.

Replace the indicated device.

 

 

 

 

 

 

 

 

XXXX-33

Illegal controller command.

Replace the indicated device.

 

 

 

 

 

 

 

XXXX-34

Invalid SCSI bus phase.

Replace the indicated device.

 

 

 

 

 

 

 

 

 

Service Reference Guide

E–11

Page 161
Image 161
HP xw6000 manual Test Error Codes, XXXX-21